diff options
author | Guenter Roeck | 2022-11-04 16:37:30 -0700 |
---|---|---|
committer | Guenter Roeck | 2022-11-04 16:47:01 -0700 |
commit | 1e699e177e339e462cdc8571e3d0fcf29665608e (patch) | |
tree | d0a6046e7c3e87c417b9f006a42242aac0dcb380 | |
parent | c4f683731db330460d909bd0ca8d5af876fcdc97 (diff) |
Revert "hwmon: (pmbus) Add regulator supply into macro"
This reverts commit 54cc3dbfc10dc3db7cb1cf49aee4477a8398fbde.
Zev Weiss reports that the reverted patch may cause a regulator
undercount. Here is his report:
... having regulator-dummy set as a supply on my PMBus regulators
(instead of having them as their own top-level regulators without
an upstream supply) leads to enable-count underflow errors when
disabling them:
# echo 0 > /sys/bus/platform/devices/efuse01/state
[ 906.094477] regulator-dummy: Underflow of regulator enable count
[ 906.100563] Failed to disable vout: -EINVAL
[ 136.992676] reg-userspace-consumer efuse01: Failed to configure state: -22
Zev reports that reverting the patch fixes the problem. So let's do that
for now.
Fixes: 54cc3dbfc10d ("hwmon: (pmbus) Add regulator supply into macro")
Cc: Marcello Sylvester Bauer <sylv@sylv.io>
Reported-by: Zev Weiss <zev@bewilderbeest.net>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
-rw-r--r-- | drivers/hwmon/pmbus/pmbus.h | 1 |
1 files changed, 0 insertions, 1 deletions
diff --git a/drivers/hwmon/pmbus/pmbus.h b/drivers/hwmon/pmbus/pmbus.h index 7daaf0caf4d3..10fb17879f8e 100644 --- a/drivers/hwmon/pmbus/pmbus.h +++ b/drivers/hwmon/pmbus/pmbus.h @@ -467,7 +467,6 @@ extern const struct regulator_ops pmbus_regulator_ops; #define PMBUS_REGULATOR_STEP(_name, _id, _voltages, _step) \ [_id] = { \ .name = (_name # _id), \ - .supply_name = "vin", \ .id = (_id), \ .of_match = of_match_ptr(_name # _id), \ .regulators_node = of_match_ptr("regulators"), \ |