diff options
author | NeilBrown | 2012-08-02 08:35:43 +1000 |
---|---|---|
committer | NeilBrown | 2012-08-02 08:35:43 +1000 |
commit | d9f691c365a83ce2530f0e46b947365c2db44ea0 (patch) | |
tree | 7348c3cb64de3445ddc4d1b4d622f7719129f365 | |
parent | f54a9d0e59c4bea3db733921ca9147612a6f292c (diff) |
md/dm-raid: DM_RAID should select MD_RAID10
Now that DM_RAID supports raid10, it needs to select that code
to ensure it is included.
Cc: Jonathan Brassow <jbrassow@redhat.com>
Reported-by: Fengguang Wu <fengguang.wu@intel.com>
Signed-off-by: NeilBrown <neilb@suse.de>
-rw-r--r-- | drivers/md/Kconfig | 5 |
1 files changed, 3 insertions, 2 deletions
diff --git a/drivers/md/Kconfig b/drivers/md/Kconfig index 10f122a3a856..1de441a6c55f 100644 --- a/drivers/md/Kconfig +++ b/drivers/md/Kconfig @@ -277,13 +277,14 @@ config DM_MIRROR needed for live data migration tools such as 'pvmove'. config DM_RAID - tristate "RAID 1/4/5/6 target" + tristate "RAID 1/4/5/6/10 target" depends on BLK_DEV_DM select MD_RAID1 + select MD_RAID10 select MD_RAID456 select BLK_DEV_MD ---help--- - A dm target that supports RAID1, RAID4, RAID5 and RAID6 mappings + A dm target that supports RAID1, RAID10, RAID4, RAID5 and RAID6 mappings A RAID-5 set of N drives with a capacity of C MB per drive provides the capacity of C * (N - 1) MB, and protects against a failure |