aboutsummaryrefslogtreecommitdiff
path: root/Documentation/devicetree/bindings/iio/pressure
diff options
context:
space:
mode:
authorBrian Masney2018-07-10 21:33:45 -0400
committerJonathan Cameron2018-07-15 09:59:05 +0100
commitd2b863baf1c7d92969c2a9dcada3c6b14e5dbbc4 (patch)
tree6d672af63d4bfc9ae174f134c3d85e546be176f2 /Documentation/devicetree/bindings/iio/pressure
parentde8df0b9c38d8f232f0df03220ff540a54eaf73d (diff)
iio: pressure: bmp280: remove unused options from device tree documentation
There are several options in the device tree documentation that are no longer relevant for the current in-kernel bmp280 driver so this patch removes them. Signed-off-by: Brian Masney <masneyb@onstation.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'Documentation/devicetree/bindings/iio/pressure')
-rw-r--r--Documentation/devicetree/bindings/iio/pressure/bmp085.txt7
1 files changed, 0 insertions, 7 deletions
diff --git a/Documentation/devicetree/bindings/iio/pressure/bmp085.txt b/Documentation/devicetree/bindings/iio/pressure/bmp085.txt
index c7198a03c906..abcab02504fb 100644
--- a/Documentation/devicetree/bindings/iio/pressure/bmp085.txt
+++ b/Documentation/devicetree/bindings/iio/pressure/bmp085.txt
@@ -8,10 +8,6 @@ Required properties:
"bosch,bme280"
Optional properties:
-- chip-id: configurable chip id for non-default chip revisions
-- temp-measurement-period: temperature measurement period (milliseconds)
-- default-oversampling: default oversampling value to be used at startup,
- value range is 0-3 with rising sensitivity.
- interrupt-parent: should be the phandle for the interrupt controller
- interrupts: interrupt mapping for IRQ
- reset-gpios: a GPIO line handling reset of the sensor: as the line is
@@ -24,9 +20,6 @@ Example:
pressure@77 {
compatible = "bosch,bmp085";
reg = <0x77>;
- chip-id = <10>;
- temp-measurement-period = <100>;
- default-oversampling = <2>;
interrupt-parent = <&gpio0>;
interrupts = <25 IRQ_TYPE_EDGE_RISING>;
reset-gpios = <&gpio0 26 GPIO_ACTIVE_LOW>;