diff options
author | Andreas Brauchli | 2018-12-13 15:43:23 +0100 |
---|---|---|
committer | Jonathan Cameron | 2018-12-16 14:05:58 +0000 |
commit | ce514124161ac2ceb13d10b6c40cbf05c8f0cc91 (patch) | |
tree | 0c19588cdb700b2ad1e429a09db9f3c1b792ae2c /Kconfig | |
parent | b170f7d48443d1ea3e4ffbf409025b5e5b1146fe (diff) |
iio: chemical: sgp30: Support Sensirion SGP30/SGPC3 sensors
Support Sensirion SGP30 and SGPC3 multi-pixel I2C gas sensors
Supported Features:
* Indoor Air Quality (IAQ) concentrations for
- tVOC (in_concentration_voc_input)
- CO2eq (in_concentration_co2_input) - SGP30 only
IAQ concentrations are periodically read out by a background thread
to allow the sensor to maintain its internal baseline.
* Gas concentration signals
- Ethanol (in_concentration_ethanol_raw)
- H2 (in_concentration_h2_raw) - SGP30 only
https://www.sensirion.com/file/datasheet_sgp30
https://www.sensirion.com/file/datasheet_sgpc3
Signed-off-by: Andreas Brauchli <andreas.brauchli@sensirion.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'Kconfig')