aboutsummaryrefslogtreecommitdiff
path: root/drivers/md/dm-raid.c
diff options
context:
space:
mode:
authorHeinz Mauelshagen2017-12-13 17:13:17 +0100
committerMike Snitzer2017-12-13 11:50:52 -0500
commit53bf5384f9b9e37c628f171366959a38c89779ca (patch)
tree5fa79fefd5cd37cebdb9b1ddbf78ac8c48bf4446 /drivers/md/dm-raid.c
parentb84cf26924cfe405993fc45fa2911cde38f3c3ac (diff)
dm raid: validate current raid sets redundancy
Verifying the current raid sets redundancy based on retrieved superblock content has to use the superblock's raid level (e.g. raid0), not the constructor requested one (e.g. raid10). Using the requested raid level of raid10 lead to a "divide error" on raid0 which defines data copies divided by to be zero. Also check for bogus data copies. Signed-off-by: Heinz Mauelshagen <heinzm@redhat.com> Signed-off-by: Mike Snitzer <snitzer@redhat.com>
Diffstat (limited to 'drivers/md/dm-raid.c')
-rw-r--r--drivers/md/dm-raid.c7
1 files changed, 6 insertions, 1 deletions
diff --git a/drivers/md/dm-raid.c b/drivers/md/dm-raid.c
index 764baa9665bb..b82b7095a671 100644
--- a/drivers/md/dm-raid.c
+++ b/drivers/md/dm-raid.c
@@ -1007,7 +1007,7 @@ static int validate_raid_redundancy(struct raid_set *rs)
!rs->dev[i].rdev.sb_page)
rebuild_cnt++;
- switch (rs->raid_type->level) {
+ switch (rs->md.level) {
case 0:
break;
case 1:
@@ -1022,6 +1022,11 @@ static int validate_raid_redundancy(struct raid_set *rs)
break;
case 10:
copies = raid10_md_layout_to_copies(rs->md.new_layout);
+ if (copies < 2) {
+ DMERR("Bogus raid10 data copies < 2!");
+ return -EINVAL;
+ }
+
if (rebuild_cnt < copies)
break;