authorGeert Uytterhoeven2015-08-04 14:28:14 +0200
committerSimon Horman2015-09-14 10:20:22 +0900
commit9b302c1acf4114d51b7f0962df0b0ddee0dc75cd (patch)
tree7303fca274cb6c0b0b6cee1bd0d32e36f36e1571 /drivers/sh/pm_runtime.c
parent6ff33f3902c3b1c5d0db6b1e2c70b6d76fba357f (diff)
drivers: sh: Disable legacy default PM Domain on emev2
EMMA Mobile EV2 doesn't have MSTP clocks. All its device drivers manage clocks explicitly, without relying on Runtime PM, so it doesn't need the legacy default PM Domain. Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org> Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
Diffstat (limited to 'drivers/sh/pm_runtime.c')
-rw-r--r--drivers/sh/pm_runtime.c3
1 files changed, 1 insertions, 2 deletions
diff --git a/drivers/sh/pm_runtime.c b/drivers/sh/pm_runtime.c
index d3d1891cda3c..ad9188138ed5 100644
--- a/drivers/sh/pm_runtime.c
+++ b/drivers/sh/pm_runtime.c
@@ -35,8 +35,7 @@ static struct pm_clk_notifier_block platform_bus_notifier = {
static int __init sh_pm_runtime_init(void)
{
if (IS_ENABLED(CONFIG_ARCH_SHMOBILE_MULTI)) {
- if (!of_machine_is_compatible("renesas,emev2") &&
- !of_machine_is_compatible("renesas,r7s72100") &&
+ if (!of_machine_is_compatible("renesas,r7s72100") &&
#ifndef CONFIG_PM_GENERIC_DOMAINS_OF
!of_machine_is_compatible("renesas,r8a73a4") &&
!of_machine_is_compatible("renesas,r8a7740") &&