net/cxgb4: use remove handler as shutdown handler
Without a shutdown handler, T4 cards behave very badly after a kexec. Some firmware calls return errors indicating allocation failures, for example. This is probably because thouse resources were not released by a BYE message to the firmware, for example. Using the remove handler guarantees we will use a well tested path. With this patch I applied, I managed to use kexec multiple times and probe and iSCSI login worked every time. Signed-off-by: Thadeu Lima de Souza Cascardo <cascardo@linux.vnet.ibm.com> Signed-off-by: David S. Miller <davem@davemloft.net>