diff options
author | Takashi Iwai | 2015-12-23 08:33:34 +0100 |
---|---|---|
committer | Takashi Iwai | 2015-12-23 08:33:34 +0100 |
commit | 59c8231089be96165735585694a801ae58ec6c95 (patch) | |
tree | 41bd60a9aec5df20e07a81fbb526c8bc05e997fc /net/mac80211/util.c | |
parent | de5126cc3c0b0f291d08fa591dcdf237bc595a56 (diff) | |
parent | 0fb0b822d157325b66c503d23332f64899bfb828 (diff) |
Merge branch 'for-linus' into for-next
Conflicts:
drivers/gpu/drm/i915/intel_pm.c
Diffstat (limited to 'net/mac80211/util.c')
-rw-r--r-- | net/mac80211/util.c | 113 |
1 files changed, 63 insertions, 50 deletions
diff --git a/net/mac80211/util.c b/net/mac80211/util.c index 74058020b7d6..33344f5a66a8 100644 --- a/net/mac80211/util.c +++ b/net/mac80211/util.c @@ -1641,6 +1641,29 @@ void ieee80211_stop_device(struct ieee80211_local *local) drv_stop(local); } +static void ieee80211_flush_completed_scan(struct ieee80211_local *local, + bool aborted) +{ + /* It's possible that we don't handle the scan completion in + * time during suspend, so if it's still marked as completed + * here, queue the work and flush it to clean things up. + * Instead of calling the worker function directly here, we + * really queue it to avoid potential races with other flows + * scheduling the same work. + */ + if (test_bit(SCAN_COMPLETED, &local->scanning)) { + /* If coming from reconfiguration failure, abort the scan so + * we don't attempt to continue a partial HW scan - which is + * possible otherwise if (e.g.) the 2.4 GHz portion was the + * completed scan, and a 5 GHz portion is still pending. + */ + if (aborted) + set_bit(SCAN_ABORTED, &local->scanning); + ieee80211_queue_delayed_work(&local->hw, &local->scan_work, 0); + flush_delayed_work(&local->scan_work); + } +} + static void ieee80211_handle_reconfig_failure(struct ieee80211_local *local) { struct ieee80211_sub_if_data *sdata; @@ -1660,6 +1683,8 @@ static void ieee80211_handle_reconfig_failure(struct ieee80211_local *local) local->suspended = false; local->in_reconfig = false; + ieee80211_flush_completed_scan(local, true); + /* scheduled scan clearly can't be running any more, but tell * cfg80211 and clear local state */ @@ -1698,6 +1723,27 @@ static void ieee80211_assign_chanctx(struct ieee80211_local *local, mutex_unlock(&local->chanctx_mtx); } +static void ieee80211_reconfig_stations(struct ieee80211_sub_if_data *sdata) +{ + struct ieee80211_local *local = sdata->local; + struct sta_info *sta; + + /* add STAs back */ + mutex_lock(&local->sta_mtx); + list_for_each_entry(sta, &local->sta_list, list) { + enum ieee80211_sta_state state; + + if (!sta->uploaded || sta->sdata != sdata) + continue; + + for (state = IEEE80211_STA_NOTEXIST; + state < sta->sta_state; state++) + WARN_ON(drv_sta_state(local, sta->sdata, sta, state, + state + 1)); + } + mutex_unlock(&local->sta_mtx); +} + int ieee80211_reconfig(struct ieee80211_local *local) { struct ieee80211_hw *hw = &local->hw; @@ -1833,50 +1879,11 @@ int ieee80211_reconfig(struct ieee80211_local *local) WARN_ON(drv_add_chanctx(local, ctx)); mutex_unlock(&local->chanctx_mtx); - list_for_each_entry(sdata, &local->interfaces, list) { - if (!ieee80211_sdata_running(sdata)) - continue; - ieee80211_assign_chanctx(local, sdata); - } - sdata = rtnl_dereference(local->monitor_sdata); if (sdata && ieee80211_sdata_running(sdata)) ieee80211_assign_chanctx(local, sdata); } - /* add STAs back */ - mutex_lock(&local->sta_mtx); - list_for_each_entry(sta, &local->sta_list, list) { - enum ieee80211_sta_state state; - - if (!sta->uploaded) - continue; - - /* AP-mode stations will be added later */ - if (sta->sdata->vif.type == NL80211_IFTYPE_AP) - continue; - - for (state = IEEE80211_STA_NOTEXIST; - state < sta->sta_state; state++) - WARN_ON(drv_sta_state(local, sta->sdata, sta, state, - state + 1)); - } - mutex_unlock(&local->sta_mtx); - - /* reconfigure tx conf */ - if (hw->queues >= IEEE80211_NUM_ACS) { - list_for_each_entry(sdata, &local->interfaces, list) { - if (sdata->vif.type == NL80211_IFTYPE_AP_VLAN || - sdata->vif.type == NL80211_IFTYPE_MONITOR || - !ieee80211_sdata_running(sdata)) - continue; - - for (i = 0; i < IEEE80211_NUM_ACS; i++) - drv_conf_tx(local, sdata, i, - &sdata->tx_conf[i]); - } - } - /* reconfigure hardware */ ieee80211_hw_config(local, ~0); @@ -1889,6 +1896,22 @@ int ieee80211_reconfig(struct ieee80211_local *local) if (!ieee80211_sdata_running(sdata)) continue; + ieee80211_assign_chanctx(local, sdata); + + switch (sdata->vif.type) { + case NL80211_IFTYPE_AP_VLAN: + case NL80211_IFTYPE_MONITOR: + break; + default: + ieee80211_reconfig_stations(sdata); + /* fall through */ + case NL80211_IFTYPE_AP: /* AP stations are handled later */ + for (i = 0; i < IEEE80211_NUM_ACS; i++) + drv_conf_tx(local, sdata, i, + &sdata->tx_conf[i]); + break; + } + /* common change flags for all interface types */ changed = BSS_CHANGED_ERP_CTS_PROT | BSS_CHANGED_ERP_PREAMBLE | @@ -2074,17 +2097,7 @@ int ieee80211_reconfig(struct ieee80211_local *local) mb(); local->resuming = false; - /* It's possible that we don't handle the scan completion in - * time during suspend, so if it's still marked as completed - * here, queue the work and flush it to clean things up. - * Instead of calling the worker function directly here, we - * really queue it to avoid potential races with other flows - * scheduling the same work. - */ - if (test_bit(SCAN_COMPLETED, &local->scanning)) { - ieee80211_queue_delayed_work(&local->hw, &local->scan_work, 0); - flush_delayed_work(&local->scan_work); - } + ieee80211_flush_completed_scan(local, false); if (local->open_count && !reconfig_due_to_wowlan) drv_reconfig_complete(local, IEEE80211_RECONFIG_TYPE_SUSPEND); |