diff options
author | Hans de Goede | 2015-03-21 15:02:55 +0100 |
---|---|---|
committer | Eduardo Valentin | 2015-04-07 13:11:29 -0700 |
commit | 7e497a7375fe5d5c5d751a71d006f4fd515bbcd8 (patch) | |
tree | 9c521532a0c0647fe29e10cad1f6bc2abdc5b8d2 /security | |
parent | 2771d00081a4e70f52a9b290dae1b68b1bdf41f6 (diff) |
thermal: Do not log an error if thermal_zone_get_temp returns -EAGAIN
Some temperature sensors only get updated every few seconds and while
waiting for the first irq reporting a (new) temperature to happen there
get_temp operand will return -EAGAIN as it does not have any data to report
yet.
Not logging an error in this case avoids messages like these from showing
up in dmesg on affected systems:
[ 1.219353] thermal thermal_zone0: failed to read out thermal zone 0
[ 2.015433] thermal thermal_zone0: failed to read out thermal zone 0
[ 2.416737] thermal thermal_zone0: failed to read out thermal zone 0
Reviewed-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'security')
0 files changed, 0 insertions, 0 deletions