aboutsummaryrefslogtreecommitdiff
path: root/tools
diff options
context:
space:
mode:
authorCosmin Tanislav2022-02-14 09:38:06 +0200
committerJonathan Cameron2022-02-21 19:33:05 +0000
commita1a5cfe70cd29a59a9a85290dfe95ed1c8df1193 (patch)
treea30d310aca35538ebd062844006851c7cf48dc3c /tools
parentb38da7feefb4c8080753eb5bf4e4db5eba0e119b (diff)
iio: introduce mag_referenced
Some accelerometers that support activity and inactivity events also support a referenced mode, in which the gravitational acceleration is taken as a point of reference before comparing the acceleration to the specified activity and inactivity magnitude. For example, in the case of the ADXL367, for activity detection, the formula is: abs(acceleration - reference) > magnitude Add a new event type that makes this behavior clear. Signed-off-by: Cosmin Tanislav <cosmin.tanislav@analog.com> Link: https://lore.kernel.org/r/20220214073810.781016-2-cosmin.tanislav@analog.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'tools')
-rw-r--r--tools/iio/iio_event_monitor.c1
1 files changed, 1 insertions, 0 deletions
diff --git a/tools/iio/iio_event_monitor.c b/tools/iio/iio_event_monitor.c
index b94a16ba5c6c..2f4581658859 100644
--- a/tools/iio/iio_event_monitor.c
+++ b/tools/iio/iio_event_monitor.c
@@ -68,6 +68,7 @@ static const char * const iio_ev_type_text[] = {
[IIO_EV_TYPE_THRESH_ADAPTIVE] = "thresh_adaptive",
[IIO_EV_TYPE_MAG_ADAPTIVE] = "mag_adaptive",
[IIO_EV_TYPE_CHANGE] = "change",
+ [IIO_EV_TYPE_MAG_REFERENCED] = "mag_referenced",
};
static const char * const iio_ev_dir_text[] = {