aboutsummaryrefslogtreecommitdiff
path: root/drivers
diff options
context:
space:
mode:
Diffstat (limited to 'drivers')
-rw-r--r--drivers/cpufreq/cpufreq-dt.c66
1 files changed, 41 insertions, 25 deletions
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c
index 92c162af5045..7789affa7eb8 100644
--- a/drivers/cpufreq/cpufreq-dt.c
+++ b/drivers/cpufreq/cpufreq-dt.c
@@ -187,6 +187,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
struct device *cpu_dev;
struct regulator *cpu_reg;
struct clk *cpu_clk;
+ unsigned long min_uV = ~0, max_uV = 0;
unsigned int transition_latency;
int ret;
@@ -206,16 +207,10 @@ static int cpufreq_init(struct cpufreq_policy *policy)
/* OPPs might be populated at runtime, don't check for error here */
of_init_opp_table(cpu_dev);
- ret = dev_pm_opp_init_cpufreq_table(cpu_dev, &freq_table);
- if (ret) {
- dev_err(cpu_dev, "failed to init cpufreq table: %d\n", ret);
- goto out_put_node;
- }
-
priv = kzalloc(sizeof(*priv), GFP_KERNEL);
if (!priv) {
ret = -ENOMEM;
- goto out_free_table;
+ goto out_put_node;
}
of_property_read_u32(np, "voltage-tolerance", &priv->voltage_tolerance);
@@ -224,30 +219,51 @@ static int cpufreq_init(struct cpufreq_policy *policy)
transition_latency = CPUFREQ_ETERNAL;
if (!IS_ERR(cpu_reg)) {
- struct dev_pm_opp *opp;
- unsigned long min_uV, max_uV;
- int i;
+ unsigned long opp_freq = 0;
/*
- * OPP is maintained in order of increasing frequency, and
- * freq_table initialised from OPP is therefore sorted in the
- * same order.
+ * Disable any OPPs where the connected regulator isn't able to
+ * provide the specified voltage and record minimum and maximum
+ * voltage levels.
*/
- for (i = 0; freq_table[i].frequency != CPUFREQ_TABLE_END; i++)
- ;
- rcu_read_lock();
- opp = dev_pm_opp_find_freq_exact(cpu_dev,
- freq_table[0].frequency * 1000, true);
- min_uV = dev_pm_opp_get_voltage(opp);
- opp = dev_pm_opp_find_freq_exact(cpu_dev,
- freq_table[i-1].frequency * 1000, true);
- max_uV = dev_pm_opp_get_voltage(opp);
- rcu_read_unlock();
+ while (1) {
+ struct dev_pm_opp *opp;
+ unsigned long opp_uV, tol_uV;
+
+ rcu_read_lock();
+ opp = dev_pm_opp_find_freq_ceil(cpu_dev, &opp_freq);
+ if (IS_ERR(opp)) {
+ rcu_read_unlock();
+ break;
+ }
+ opp_uV = dev_pm_opp_get_voltage(opp);
+ rcu_read_unlock();
+
+ tol_uV = opp_uV * priv->voltage_tolerance / 100;
+ if (regulator_is_supported_voltage(cpu_reg, opp_uV,
+ opp_uV + tol_uV)) {
+ if (opp_uV < min_uV)
+ min_uV = opp_uV;
+ if (opp_uV > max_uV)
+ max_uV = opp_uV;
+ } else {
+ dev_pm_opp_disable(cpu_dev, opp_freq);
+ }
+
+ opp_freq++;
+ }
+
ret = regulator_set_voltage_time(cpu_reg, min_uV, max_uV);
if (ret > 0)
transition_latency += ret * 1000;
}
+ ret = dev_pm_opp_init_cpufreq_table(cpu_dev, &freq_table);
+ if (ret) {
+ pr_err("failed to init cpufreq table: %d\n", ret);
+ goto out_free_priv;
+ }
+
/*
* For now, just loading the cooling device;
* thermal DT code takes care of matching them.
@@ -286,9 +302,9 @@ static int cpufreq_init(struct cpufreq_policy *policy)
out_cooling_unregister:
cpufreq_cooling_unregister(priv->cdev);
- kfree(priv);
-out_free_table:
dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);
+out_free_priv:
+ kfree(priv);
out_put_node:
of_node_put(np);
out_put_reg_clk: