aboutsummaryrefslogtreecommitdiff
path: root/drivers/hwmon/pmbus/pmbus.h
AgeCommit message (Collapse)Author
2022-11-04Revert "hwmon: (pmbus) Add regulator supply into macro"Guenter Roeck
This reverts commit 54cc3dbfc10dc3db7cb1cf49aee4477a8398fbde. Zev Weiss reports that the reverted patch may cause a regulator undercount. Here is his report: ... having regulator-dummy set as a supply on my PMBus regulators (instead of having them as their own top-level regulators without an upstream supply) leads to enable-count underflow errors when disabling them: # echo 0 > /sys/bus/platform/devices/efuse01/state [ 906.094477] regulator-dummy: Underflow of regulator enable count [ 906.100563] Failed to disable vout: -EINVAL [ 136.992676] reg-userspace-consumer efuse01: Failed to configure state: -22 Zev reports that reverting the patch fixes the problem. So let's do that for now. Fixes: 54cc3dbfc10d ("hwmon: (pmbus) Add regulator supply into macro") Cc: Marcello Sylvester Bauer <sylv@sylv.io> Reported-by: Zev Weiss <zev@bewilderbeest.net> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-07-13hwmon: (pmbus/ltc2978) Set voltage resolutionMårten Lindahl
The LTC2977 regulator does not set the regulator_desc .n_voltages value which is needed in order to let the regulator core list the regulator voltage range. This patch defines a regulator_desc with a voltage range, and uses it for defining voltage resolution for regulators LTC2972/LTC2974/LTC2975/ LTC2977/LTC2978/LTC2979/LTC2980/LTM2987 based on that they all have a 16 bit ADC with the same stepwise 122.07uV resolution. It also scales the resolution to a 1mV resolution which is easier to handle. Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com> Link: https://lore.kernel.org/r/20220614095144.3472305-1-marten.lindahl@axis.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-07-13hwmon: (pmbus) Add IEEE 754 half precision support to PMBus coreGuenter Roeck
Add support for the IEEE 754 half precision data format as specified in PMBus v1.3.1. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-20hwmon: (pmbus) Introduce and use write_byte_data callbackMårten Lindahl
Some of the pmbus core functions uses pmbus_write_byte_data, which does not support driver callbacks for chip specific write operations. This could potentially influence some specific regulator chips that for example need a time delay before each data access. Lets add support for driver callback with _pmbus_write_byte_data. Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com> Link: https://lore.kernel.org/r/20220428144039.2464667-2-marten.lindahl@axis.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-03-17hwmon: (pmbus) Add Vin unit off handlingBrandon Wyman
If there is an input undervoltage fault, reported in STATUS_INPUT command response, there is quite likely a "Unit Off For Insufficient Input Voltage" condition as well. Add a constant for bit 3 of STATUS_INPUT. Update the Vin limit attributes to include both bits in the mask for clearing faults. If an input undervoltage fault occurs, causing a unit off for insufficient input voltage, but the unit is off bit is not cleared, the STATUS_WORD will not be updated to clear the input fault condition. Including the unit is off bit (bit 3) allows for the input fault condition to completely clear. Signed-off-by: Brandon Wyman <bjwyman@gmail.com> Link: https://lore.kernel.org/r/20220317232123.2103592-1-bjwyman@gmail.com Fixes: b4ce237b7f7d3 ("hwmon: (pmbus) Introduce infrastructure to detect sensors and limit registers") [groeck: Dropped unnecessary ()] Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27hwmon: (pmbus) Add regulator supply into macroMarcello Sylvester Bauer
Add regulator supply into PWBUS_REGULATOR macro. This makes it optional to define a vin-supply in DT. Not defining a supply will add a dummy regulator supply instead and only cause the following debug output: ``` Looking up vin-supply property in node [...] failed ``` Signed-off-by: Marcello Sylvester Bauer <sylv@sylv.io> Link: https://lore.kernel.org/r/58f2ff7b90233fad3d7ae2e9d66d5192e2c1ac01.1645437439.git.sylv@sylv.io Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-06-17hwmon: (pmbus) Increase maximum number of phases per pageVadim Pasternak
Increase maximum number of phases from 8 to 10 to support multi-phase devices allowing up to 10 phases. Signed-off-by: Vadim Pasternak <vadimp@nvidia.com> Link: https://lore.kernel.org/r/20210511055619.118104-2-vadimp@nvidia.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-04-20hwmon: (pmbus) Add pmbus_set_update() function to set update flagErik Rosen
For the STPDDC60 chip, the vout alarm-limits are represented as an offset relative to the commanded output voltage. This means that the limits are dynamic and must not be cached by the pmbus driver. This patch adds a pmbus_set_sensor() function to pmbus_core to be able to set the update flag on selected sensors after auto-detection of limit attributes. Signed-off-by: Erik Rosen <erik.rosen@metormote.com> Link: https://lore.kernel.org/r/20210218115249.28513-2-erik.rosen@metormote.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-12-02hwmon: (pmbus) shrink code and remove pmbus_do_remove()Bartosz Golaszewski
The only action currently performed in pmbus_do_remove() is removing the debugfs hierarchy. We can schedule a devm action at probe time and remove pmbus_do_remove() entirely from all pmbus drivers. Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com> Link: https://lore.kernel.org/r/20201026105352.20359-1-brgl@bgdev.pl [groeck: Removed references to pmbus_do_remove from documentation] Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-09-23hwmon (pmbus) use simple i2c probe functionStephen Kitt
pmbus_do_probe doesn't use the id information provided in its second argument, so this can be removed, which then allows using the single-parameter i2c probe function ("probe_new") for probes. This avoids scanning the identifier tables during probes. Drivers which didn't use the id are converted as-is; drivers which did are modified as follows: * if the information in i2c_client is sufficient, that's used instead (client->name); * configured v. probed comparisons are performed by comparing the configured name to the detected name, instead of the ids; this involves strcmp but is still cheaper than comparing all the device names when scanning the tables; * anything else is handled by calling i2c_match_id() with the same level of error-handling (if any) as before. Additionally, the mismatch message in the ltc2978 driver is adjusted so that it no longer assumes that the driver_data is an index into ltc2978_id. Signed-off-by: Stephen Kitt <steve@sk2.org> Acked-by: Wolfram Sang <wsa@kernel.org> Link: https://lore.kernel.org/r/20200808210004.30880-1-steve@sk2.org Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-09-23hwmon: (pmbus/core) Add support for rated attributesZbigniew Lukwinski
Adding implementation for new attributes (rated_min/rated_max) to cover PMBus specification about rated values reporting: MFR_VIN_MIN, MFR_VIN_MAX, MFR_IIN_MAX, MFR_PIN_MAX, MFR_VOUT_MIN, MFR_VOUT_MAX, MFR_IOUT_MAX, MFR_POUT_MAX, MFR_MAX_TEMP_1/2/3. Tested with OpenBMC stack. All rated attributes were available and reported correct values. Signed-off-by: Zbigniew Lukwinski <zbigniew.lukwinski@linux.intel.com> Link: https://lore.kernel.org/r/1596224237-32280-4-git-send-email-zbigniew.lukwinski@linux.intel.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-03-08hwmon: (pmbus) Implement multi-phase supportGuenter Roeck
Some PMBus chips support multiple phases, and report telemetry such as input current, output current, or temperature for each phase. Add support for such chips to the PMBus core. Start with a maximum of 8 phases per page, and assume that supported sensors per phase are similar for all pages. Only support per-phase telemetry attributes, no limits or alarms. As part of this patch, set the initial page variable to 0xff to ensure that the page is updated when the first page command is issued. Also only issue page commands if the chip supports more than one page. Cc: Vadim Pasternak <vadimp@mellanox.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-03-08hwmon: (pmbus) Add 'phase' parameter where needed for multi-phase supportGuenter Roeck
In preparation for multi-phase support, add 'phase' parameter to read_word and set_page functions. Actual multi-phase support will be added in a subsequent patch. Cc: Vadim Pasternak <vadimp@mellanox.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-03-08hwmon: (pmbus) Add IC_DEVICE_ID and IC_DEVICE_REV command definitionsGuenter Roeck
Recent PMBus versions added IC_DEVICE_ID and IC_DEVICE_REV commands as additional means to identify the chip. Add command definitions to pmbus.h include file. Cc: Vadim Pasternak <vadimp@mellanox.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-01-23hwmon: (pmbus/core) Add support for Intel IMVP9 and AMD 6.25mV modesVadim Pasternak
Extend "vrm_version" with the type for Intel IMVP9 and AMD 6.25mV VID modes. Add calculation for those types. Signed-off-by: Vadim Pasternak <vadimp@mellanox.com> Link: https://lore.kernel.org/r/20200113150841.17670-3-vadimp@mellanox.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-01-23hwmon: (pmbus/core) Add support for vid mode detection per page basesVadim Pasternak
Add support for VID protocol detection per page bases, instead of detecting it based on "PMBU_VOUT" readout from page 0 for all the pages supported by particular device. The reason that some devices allows to configure different VID modes per page within the same device. Patch modifies the field "vrm_version" within the structure "pmbus_driver_info" to be per page array. Signed-off-by: Vadim Pasternak <vadimp@mellanox.com> Link: https://lore.kernel.org/r/20200113150841.17670-2-vadimp@mellanox.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2020-01-23hwmon: (pmbus) Detect if chip is write protectedGuenter Roeck
If a chip is write protected, we can not change any limits, and we can not clear status flags. This may be the reason why clearing status flags is reported to not work for some chips. Detect the condition in the pmbus core. If the chip is write protected, set limit attributes as read-only, and set the flag indicating that the status flag should be ignored. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2019-05-24treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 61Thomas Gleixner
Based on 1 normalized pattern(s): this program is free software you can redistribute it and or modify it under the terms of the gnu general public license as published by the free software foundation either version 2 of the license or at your option any later version this program is distributed in the hope that it will be useful but without any warranty without even the implied warranty of merchantability or fitness for a particular purpose see the gnu general public license for more details you should have received a copy of the gnu general public license along with this program if not write to the free software foundation inc 675 mass ave cambridge ma 02139 usa extracted by the scancode license scanner the SPDX license identifier GPL-2.0-or-later has been chosen to replace the boilerplate/reference in 441 file(s). Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Reviewed-by: Michael Ellerman <mpe@ellerman.id.au> (powerpc) Reviewed-by: Richard Fontana <rfontana@redhat.com> Reviewed-by: Allison Randal <allison@lohutok.net> Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org> Cc: linux-spdx@vger.kernel.org Link: https://lkml.kernel.org/r/20190520071858.739733335@linutronix.de Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-04-15pmbus: support for custom sysfs attributeskrzysztof.adamski@nokia.com
This patch makes it possible to pass custom struct attribute_group array via the pmbus_driver_info struct so that those can be added to the attribute groups passed to hwmon_device_register_with_groups(). This makes it possible to register custom sysfs attributes by PMBUS drivers similar to how you can do this with most other busses/classes. Signed-off-by: Krzysztof Adamski <krzysztof.adamski@nokia.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2019-04-15hwmon: (pmbus) Introduce PMBUS_VIRT_*_SAMPLES registersAdamski, Krzysztof (Nokia - PL/Wroclaw)
Those virtual registers can be used to export manufacturer specific functionality for controlling the number of samples for average values reported by the device. Signed-off-by: Krzysztof Adamski <krzysztof.adamski@nokia.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-01-02hwmon: (pmbus) Export pmbus device debugfs directory entryEdward A. James
Pmbus client drivers, if they want to use debugfs, should use the same root directory as the pmbus debugfs entries are using. Therefore, export the device dentry for the pmbus client. Signed-off-by: Edward A. James <eajames@us.ibm.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-01-02hwmon: (pmbus) Add virtual page config bitAndrew Jeffery
Some circumstances call for virtual pages, to expose multiple values packed into an extended PMBus register in a manner non-compliant with the PMBus standard. An example of this is the Maxim MAX31785 controller, which extends the READ_FAN_SPEED_1 PMBus register from two to four bytes to support tach readings for both rotors of a dual rotor fan. This extended register contains two word-sized values, one reporting the rate of the fastest rotor, the other the rate of the slowest. The concept of virtual pages aids this situation by mapping the page number onto the value to be selected from the vectored result. We should not try to set virtual pages on the device as such a page explicitly doesn't exist; add a flag so we can avoid doing so. Signed-off-by: Andrew Jeffery <andrew@aj.id.au> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-01-02hwmon: (pmbus) Add fan control supportAndrew Jeffery
Expose fanX_target, pwmX and pwmX_enable hwmon sysfs attributes. Fans in a PMBus device are driven by the configuration of two registers, FAN_CONFIG_x_y and FAN_COMMAND_x: FAN_CONFIG_x_y dictates how the fan and the tacho operate (if installed), while FAN_COMMAND_x sets the desired fan rate. The unit of FAN_COMMAND_x is dependent on the operational fan mode, RPM or PWM percent duty, as determined by the corresponding configuration in FAN_CONFIG_x_y. The mapping of fanX_target, pwmX and pwmX_enable onto FAN_CONFIG_x_y and FAN_COMMAND_x is implemented with the addition of virtual registers to facilitate the necessary side-effects of each access: 1. PMBUS_VIRT_FAN_TARGET_x 2. PMBUS_VIRT_PWM_x 3. PMBUS_VIRT_PWM_ENABLE_x Some complexity arises with the fanX_target and pwmX attributes both mapping onto FAN_COMMAND_x: There is no general mapping between PWM percent duty and RPM, so we can't display values in either attribute in terms of the other (which in my mind is the intuitive, if impossible, behaviour). This problem also affects the pwmX_enable attribute which allows userspace to switch between full speed, manual PWM and a number of automatic control modes, possibly including a switch to RPM behaviour (e.g. automatically adjusting PWM duty to reach a RPM target, the behaviour of fanX_target). The next most intuitive behaviour is for fanX_target and pwmX to simply be independent, to retain their most recently set value even if that value is not active on the hardware (due to switching to the alternative control mode). This property of retaining the value independent of the hardware state has useful results for both userspace and the kernel: Userspace always sees a sensible value in the attribute (the last thing it was set to, as opposed to 0 or receiving an error on read), and the kernel can use the attributes as a value cache. This latter point eases the implementation of pwmX_enable, which can look up the associated pmbus_sensor object, take its cached value and apply it to hardware on changing control mode. This ensures we will not arbitrarily set a PWM value as an RPM value or vice versa, and we can assume that the RPM or PWM value set was sensible at least at some point in the past. Finally, the DIRECT mode coefficients of some controllers is different between RPM and PWM percent duty control modes, so PSC_PWM is introduced to capture the necessary coefficients. As pmbus core had no PWM support previously PSC_FAN continues to be used to capture the RPM DIRECT coefficients, but in order to avoid falsely applying RPM scaling to PWM values I have introduced the PMBUS_HAVE_PWM12 and PMB_BUS_HAVE_PWM34 feature bits. These feature bits allow drivers to explicitly declare PWM support in order to have the attributes exposed. Signed-off-by: Andrew Jeffery <andrew@aj.id.au> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2017-10-29hwmon: (pmbus/core) Prevent unintentional setting of page to 0xFFEdward A. James
The pmbus core may call read/write word data functions with a page value of -1, intending to perform the operation without setting the page. However, the read/write word data functions accept only unsigned 8-bit page numbers, and therefore cannot check for negative page number to avoid setting the page. This results in setting the page number to 0xFF. This may result in errors or undefined behavior of some devices (specifically the ir35221, which allows the page to be set to 0xFF, but some subsequent operations to read registers may fail). Switch the pmbus_set_page page parameter to an integer and perform the check for negative page there. Make read/write functions consistent in accepting an integer page number parameter. Signed-off-by: Edward A. James <eajames@us.ibm.com> Fixes: cbcdec6202c9 ("hwmon: (pmbus): Access word data for STATUS_WORD") Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2017-08-30hwmon: (pmbus) Add support for Intel VID protocol VR13Vadim Pasternak
The below lists of VOUT_MODE command readout with their related VID protocols, Digital to Analog Converter steps: - VR13.0 mode, 10-mV DAC - 0x24 - VR13.0 mode, 5-mV DAC - 0x27 Signed-off-by: Vadim Pasternak <vadimp@mellanox.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2015-08-19hwmon: (pmbus) Use BIT macroGuenter Roeck
Using the BIT macro makes the code a little easier to read. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2015-08-17hwmon: (pmbus) Convert command register definitions to enumGuenter Roeck
This will simplify adding new virtual commands. Tested-by: Michael Jones <mike@proclivis.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2015-08-09hwmon: (pmbus) Add support for VR12Guenter Roeck
Newer chips such as MAX20751 support VR12. Add support for it. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2015-08-09hwmon: (pmbus) Add support for lowest power value attributesGuenter Roeck
Add support for powerX_input_lowest for both input and output power. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2015-08-09hwmon: (pmbus_core) Constify pmbus_regulator_opsAxel Lin
pmbus_regulator_ops is not modified after initialized, so make it const. Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2015-08-09hwmon: (pmbus) Explicitly set regulator type for pmbus_regulator_opsAxel Lin
The pmbus_regulator_ops is for voltage regulators, so explicitly set regulator type for better readability. Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2014-11-30hwmon: (pmbus) Add regulator supportAlan Tull
Add support for simple on/off control of each channel. To add regulator support, the pmbus part driver needs to add regulator_desc information and number of regulators to its pmbus_driver_info struct. regulator_desc can be declared using default macro for a regulator (PMBUS_REGULATOR) that is in pmbus.h The regulator_init_data can be initialized from either platform data or the device tree. Signed-off-by: Alan Tull <atull@opensource.altera.com> Reviewed-by: Mark Brown <broonie@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2014-11-30hwmon: (pmbus) add helpers for byte write and read modify writeAlan Tull
Add two helper functions: * pmbus_write_byte_data = paged byte write * pmbus_update_byte_data = paged byte read/modify/write Signed-off-by: Alan Tull <atull@opensource.altera.com> Cc: Mark Brown <broonie@kernel.org> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2013-02-06hwmon: (pmbus) Add function to clear sensor cacheGuenter Roeck
For PMBus chips, modifying one limit register may affect other limits. Since limits are all cached in the PMBus core driver, related changes are not reflected in reported limits. Introduce function to clear the attribute cache. After calling this function, the core pmbus driver re-reads all cached values. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2013-02-06hwmon: (pmbus) Add support for additional voltage sensorGuenter Roeck
Some PMBus chips support monitoring an additional non-standard voltage. While this voltage can in many cases be supported by simulating an additional sensor page, this does not work in all cases. Specifically, it is problematic if the data format is linear and the voltage is reported in LINEAR11 format. Since output voltages use LINEAR16, and the exponent for LINEAR16 data is chip-wide and fixed, this can result in overflows. To solve this problem, add support for an additional virtual input voltage, call it 'vmon', and treat this voltage as input voltage (which, when the chip supports linear data format, uses LINEAR11). Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2012-03-18hwmon: (pmbus) Add more virtual registersGuenter Roeck
Add PMBUS_VIRT_READ_TEMP_AVG, PMBUS_VIRT_READ_TEMP2_AVG, PMBUS_VIRT_READ_POUT_AVG, PMBUS_VIRT_READ_POUT_MAX, and PMBUS_VIRT_RESET_POUT_HISTORY. We'll need those for MAX34446. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2012-03-18hwmon: (pmbus) Simplify remove functionsGuenter Roeck
Since devm_kzalloc() is now used to allocate driver memory, the client driver remove function has no purpose other than to call pmbus_do_remove(). This means we can get rid of it by redefining pmbus_do_remove() to use the same prototype, and pointing to it directly. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2011-10-24hwmon: (pmbus) Add support for TEMP2 peak attributesGuenter Roeck
At least one PMBus chip supports peak attributes for READ_TEMPERATURE2. Add virtual registers to be able to report it to the user. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-10-24hwmon: (pmbus) Don't return errors from driver remove functionsGuenter Roeck
Driver remove functions have an error return value, but rarely return an error in practice. If a driver does return an error from its remove function, the driver won't be unloaded and is expected to stay alive. pmbus_do_remove() is defined as returning an int, but always returns 0 (no error). Calling code passes that return value on to high level driver remove functions, but does not evaluate it and removes driver data even if pmbus_do_remove() returned an error (which it in practice never does). Even if this code could never cause a real problem, it is nevertheless conceptually wrong. To reduce confusion and simplify the code, change pmbus_do_remove() to be a void function, and have PMBus client drivers always return zero in their driver remove functions. Reported-by: Jean Delvare <khali@linux-fr.org> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-10-24hwmon: (pmbus) Add comments explaining internal driver API return valuesGuenter Roeck
Return values for functions reading/writing manufacturer specific registers are poorly explained. Add comments to improve documentation. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org>
2011-08-11hwmon: (pmbus) Virtualize pmbus_write_byteGuenter Roeck
With virtual pages and to be able to handle more chips, it is necessary to virtualise pmbus_write_byte(). Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add client driver for LM25066, LM5064, and LM5066Guenter Roeck
PMBus client driver supporting National Semiconductor LM25066, LM5064, and LM5066. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for peak attributesGuenter Roeck
Most PMBus devices provide manufacturer specific commands to read low and/or high peak values for some or all of its sensors. To support providing those values as lowest/highest attributes to the user, introduce virtual PMBus commands. Those commands reside outside the normal command set and have to be implemented in device specific code, which map the virtual commands to device specific commands. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for virtual pagesGuenter Roeck
Some PMBus chips have non-standard sensor registers. An easy way to support such sensors is to introduce virtual pages and map the non-standard registers into standard registers on an extra page. For this to work, the code verifying if the configured number of pages exists has to be removed. Since a wrong number of pages can only be configured in a front-end driver, this should not have a practical impact since the resulting errors should be found during development and testing. Also, functions to read the chip status while checking if a command register exists must be modified to no longer set the page register before reading the status, since the physical page associated with the checked register may not exist. This does not make a functional difference since the page was already set when the attempt to read the register was made. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Support reading and writing of word registers in device ↵Guenter Roeck
specific code Some PMBus devices use non-standard registers for some of the sensors and/or limits. To support such devices, add code to support reading and writing of word size registers in device specific code. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Add support for VID output voltage modeGuenter Roeck
In VID mode, output voltages are measured and reported as VID values, and have to be converted to voltages using VID conversion tables or functions. Support is added for VR11 only at this time. This patch enables support for PMBus devices supporting VID VR11 based output voltage selection such as NCP4200 and NCP4208. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
2011-07-28hwmon: (pmbus) Move PMBus drivers to drivers/hwmon/pmbusGuenter Roeck
Since the number of PMBus drivers is getting large, move them into directory drivers/hwmon/pmbus to improve readability and scalability. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>