aboutsummaryrefslogtreecommitdiff
path: root/drivers/net/can
AgeCommit message (Collapse)Author
2010-02-26can: ti hecc module : add platform specific initialization callback.Sriramakrishnan
CAN module on AM3517 requires programming of IO expander as part of init sequence - to enable CAN PHY. Added platform specific callback to handle phy control(switch on /off). Signed-off-by: Sriramakrishnan <srk@ti.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-02-26can: netlink support for bus-error reporting and countersWolfgang Grandegger
This patch makes the bus-error reporting configurable and allows to retrieve the CAN TX and RX bus error counters via netlink interface. I have added support for the SJA1000. The TX and RX bus error counters are also copied to the data fields 6..7 of error messages when state changes are reported. Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-02-22can:ti_hecc: Add pm hook-upSriram
Added the suspend and resume implementation in the HECC (CAN) driver. Signed-off-by: K R Baalaaji <krbaalaaji@ti.com> Signed-off-by: Sriramakrishnan <srk@ti.com> Acked-by: Anant Gole <anantgole@ti.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-02-04can: ems_usb: removed duplicated code setting local echo supportThadeu Lima de Souza Cascardo
Signed-off-by: Thadeu Lima de Souza Cascardo <cascardo@holoscopio.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-02-03can: mcp251x: Move to threaded interrupts instead of workqueues.Christian Pellegrin
This patch addresses concerns about efficiency of handling incoming packets. Handling of interrupts is done in a threaded interrupt handler which has a smaller latency than workqueues. This change needed a rework of the locking scheme that was much simplified. Some other (more or less longstanding) bugs are fixed: utilization of just half of the RX buffers, useless wait for interrupt on open, more reliable reset sequence. The MERR interrupt is not used anymore: it overloads the CPU in error-passive state without any additional information. One shot mode is disabled because it's not clear if it can be handled efficiently on this CAN controller. Signed-off-by: Christian Pellegrin <chripell@fsfe.org> Acked-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-02-03trivial: remove duplicated "from" in CAN USB EMS Kconfig helpThadeu Lima de Souza Cascardo
Signed-off-by: Thadeu Lima de Souza Cascardo <cascardo@holoscopio.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-02-03can: add support for CAN interface cards based on the PLX90xx PCI bridgePavel Cheblakov
This driver is for CAN interface cards based on the PLX90xx PCI bridge. Driver supports now: - Adlink PCI-7841/cPCI-7841 card (http://www.adlinktech.com/) - Adlink PCI-7841/cPCI-7841 SE card - Marathon CAN-bus-PCI card (http://www.marathon.ru/) - TEWS TECHNOLOGIES TPMC810 card (http://www.tews.com/) Changes since v1: - Added some defines for static inline int plx_pci_check_sja1000(...) - static struct pci_device_id plx_pci_tbl[] replaced by static DEFINE_PCI_DEVICE_TABLE(plx_pci_tbl) - Typo fixed Signed-off-by: Pavel Cheblakov <P.B.Cheblakov@inp.nsk.su> Acked-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-01-15can: mscan-mpc5xxx: fix broken support for the MPC5200Wolfgang Grandegger
Due to an invalid "#ifdef CONFIG_PPC_MPC5200", the real clock setup function was not called for the MPC5200. Signed-off-by: Wolfgang Grandegger <wg@denx.de> Acked-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-01-15can: Proper ctrlmode handling for CAN devicesChristian Pellegrin
This patch adds error checking of ctrlmode values for CAN devices. As an example all availabe bits are implemented in the mcp251x driver. Signed-off-by: Christian Pellegrin <chripell@fsfe.org> Acked-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-01-12can: Unify droping of invalid tx skbs and netdev statsOliver Hartkopp
To prevent the CAN drivers to operate on invalid socketbuffers the skbs are now checked and silently dropped at the xmit-function consistently. Also the netdev stats are consistently using the CAN data length code (dlc) for [rx|tx]_bytes now. Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net> Acked-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-01-10Merge branch 'master' of ↵David S. Miller
master.kernel.org:/pub/scm/linux/kernel/git/davem/net-2.6 Conflicts: drivers/net/benet/be_cmds.h include/linux/sysctl.h
2010-01-08can: mscan-mpc5xxx: add support for the MPC512x processorWolfgang Grandegger
The main differences compared to the MSCAN on the MPC5200 are: - More flexibility in choosing the CAN source clock and frequency: Three different clock sources can be selected: "ip", "ref" or "sys". For the latter two, a clock divider can be defined as well. If the clock source is not specified by the device tree, we first try to find an optimal CAN source clock based on the system clock. If that is not possible, the reference clock will be used. - The behavior of bus-off recovery is configurable: To comply with the usual handling of Socket-CAN bus-off recovery, "recovery on request" is selected (instead of automatic recovery). Note that only MPC5121 Rev. 2 and later is supported. Signed-off-by: Wolfgang Grandegger <wg@denx.de> Reviewed-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-01-08can: mscan: fix improper return if dlc < 8 in start_xmit functionWolfgang Grandegger
The start_xmit function of the MSCAN Driver did return improperly if the CAN dlc check failed (skb not freed and invalid return code). This patch adds a proper check of the frame lenght and data size and returns now correctly. The invalid skb packets are dropped silently as suggested by David Miller in the thread "[RFC] ndo_validate_skb: Let the netdev check a valid skb content" on the netdev mailing list. Furthermore, a typo has been fixed. Signed-off-by: Wolfgang Grandegger <wg@denx.de> Reviewed-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-01-07drivers/net/: use DEFINE_PCI_DEVICE_TABLE()Alexey Dobriyan
Use DEFINE_PCI_DEVICE_TABLE() so we get place PCI ids table into correct section in every case. Signed-off-by: Alexey Dobriyan <adobriyan@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2010-01-03drivers/net/can: Correct NULL testJulia Lawall
Test the just-allocated value for NULL rather than some other value. The semantic patch that makes this change is as follows: (http://coccinelle.lip6.fr/) // <smpl> @@ expression x,y; statement S; @@ x = \(kmalloc\|kcalloc\|kzalloc\)(...); ( if ((x) == NULL) S | if ( - y + x == NULL) S ) // </smpl> Signed-off-by: Julia Lawall <julia@diku.dk> Acked-by: Oliver Hartkopp <oliver@hartkopp.net> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-12-18can/at91: don't check platform_get_irq's return value against zeroUwe Kleine-König
platform_get_irq returns -ENXIO on failure, so !irq was probably always true. Better use (int)irq <= 0. Note that a return value of zero is still handled as error even though this could mean irq0. This is a followup to 305b3228f9ff4d59f49e6d34a7034d44ee8ce2f0 that changed the return value of platform_get_irq from 0 to -ENXIO on error. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-12-13can: CAN_MCP251X should depend on HAS_DMAGeert Uytterhoeven
When building for Sun 3: drivers/net/can/mcp251x.c:1074: undefined reference to `dma_free_coherent' drivers/net/can/mcp251x.c:976: undefined reference to `dma_alloc_coherent' drivers/net/can/mcp251x.c:1050: undefined reference to `dma_free_coherent' Signed-off-by: Geert Uytterhoeven <geert@linux-m68k.org> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-12-13can: Fix data length code handling in rx pathOliver Hartkopp
A valid CAN dataframe can have a data length code (DLC) of 0 .. 8 data bytes. When reading the CAN controllers register the 4-bit value may contain values from 0 .. 15 which may exceed the reserved space in the socket buffer! The ISO 11898-1 Chapter 8.4.2.3 (DLC field) says that register values > 8 should be reduced to 8 without any error reporting or frame drop. This patch introduces a new helper macro to cast a given 4-bit data length code (dlc) to __u8 and ensure the DLC value to be max. 8 bytes. The different handlings in the rx path of the CAN netdevice drivers are fixed. Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-12-11can: add the driver for Analog Devices Blackfin on-chip CAN controllersBarry Song
Signed-off-by: Barry Song <21cnbao@gmail.com> Signed-off-by: H.J. Oertel <oe@port.de> Signed-off-by: Wolfgang Grandegger <wg@grandegger.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-12-03drivers/net: Move && and || to end of previous lineJoe Perches
Only files where David Miller is the primary git-signer. wireless, wimax, ixgbe, etc are not modified. Compile tested x86 allyesconfig only Not all files compiled (not x86 compatible) Added a few > 80 column lines, which I ignored. Existing checkpatch complaints ignored. Signed-off-by: Joe Perches <joe@perches.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-18drivers/net/can: remove exceptional & on function nameJulia Lawall
In this file, function names are otherwise used as pointers without &. A simplified version of the semantic patch that makes this change is as follows: (http://coccinelle.lip6.fr/) // <smpl> @r@ identifier f; @@ f(...) { ... } @@ identifier r.f; @@ - &f + f // </smpl> Signed-off-by: Julia Lawall <julia@diku.dk> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-18can: fix setting mcp251x bit timing on openChristian Pellegrin
Signed-off-by: Christian Pellegrin <chripell@fsfe.org> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: improve buildWolfram Sang
- move Kconfig entries to the subdirectory - do remaining renames of mpc52xx to mpc5xxx Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: add error path to mscan_open()Wolfram Sang
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: replace hardcoded values with definesWolfram Sang
Not all hardcoded values have been replaced as this made the code quite unreadable. IMHO this compromise serves the purpose of readability. Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mpc52xx_can: improve properties and their descriptionWolfram Sang
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Cc: devicetree-discuss@ozlabs.org Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mpc52xx_can: refactor clock-get routineWolfram Sang
Merge two functions into one. The result is smaller as they can now share some variables. Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: drop assignment in while-constructWolfram Sang
As suggested by Wolfgang Grandegger. Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: fix function annotationsWolfram Sang
- use extern where apropriate - don't export symbols Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: use {clr|set}bits8 macrosWolfram Sang
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: drop support for CAN_MODE_{SLEEP|STOP}Wolfram Sang
The upper layer does not support it yet. Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: trivial fixesWolfram Sang
- remove whitespaces - use ! and ?: when apropriate - make braces consistent Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17net/can/mscan: move defines into .h fileWolfram Sang
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-17Merge branch 'master' of ↵David S. Miller
master.kernel.org:/pub/scm/linux/kernel/git/davem/net-2.6 Conflicts: drivers/net/can/Kconfig
2009-11-13net/can: add driver for mscan family & mpc52xx_mscanWolfram Sang
Taken from socketcan-svn, fixed remaining todos, cleaned up, tested with a phyCORE-MPC5200B-IO and a custom board. Signed-off-by: Wolfram Sang <w.sang@pengutronix.de> Cc: Wolfgang Grandegger <wg@grandegger.com> Cc: Grant Likely <grant.likely@secretlab.ca> Cc: David Miller <davem@davemloft.net> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-13can: add the missing netlink get_xstats_size callbackWolfgang Grandegger
This patch adds the missing "get_xstats_size" callback for the netlink interface, which is required if "fill_xstats" is used, as pointed out by Patrick McHardy. Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-13can: Fix driver Kconfig structureOliver Hartkopp
In 2.6.32-rc the new EMS USB CAN driver was contributed and added the Kconfig entry right behind an entry of the same *vendor*. This teared the SJA1000 based driver selection into pieces. This fix cleans up the 2.6.32-rc Kconfig files for the CAN drivers and moves the SJA1000 and USB Kconfig portions into the belonging directories. As there are many new CAN drivers in the queue getting this cleanup into 2.6.32-rc would massively reduce the problems for the upcoming drivers. Thanks, Oliver Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-08Merge branch 'master' of ↵David S. Miller
master.kernel.org:/pub/scm/linux/kernel/git/davem/net-2.6 Conflicts: drivers/net/can/usb/ems_usb.c
2009-11-08can: Driver for the Microchip MCP251x SPI CAN controllersChristian Pellegrin
Signed-off-by: Christian Pellegrin <chripell@fsfe.org> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-08net: Support specifying the network namespace upon device creation.Eric W. Biederman
There is no good reason to not support userspace specifying the network namespace during device creation, and it makes it easier to create a network device and pass it to a child network namespace with a well known name. We have to be careful to ensure that the target network namespace for the new device exists through the life of the call. To keep that logic clear I have factored out the network namespace grabbing logic into rtnl_link_get_net. In addtion we need to continue to pass the source network namespace to the rtnl_link_ops.newlink method so that we can find the base device source network namespace. Signed-off-by: Eric W. Biederman <ebiederm@aristanetworks.com> Acked-by: Eric Dumazet <eric.dumazet@gmail.com>
2009-11-08can: fix WARN_ON dump in net/core/rtnetlink.c:rtmsg_ifinfo()Wolfgang Grandegger
On older kernels, e.g. 2.6.27, a WARN_ON dump in rtmsg_ifinfo() is thrown when the CAN device is registered due to insufficient skb space, as reported by various users. This patch adds the rtnl_link_ops "get_size" to fix the problem. I think this patch is required for more recent kernels as well, even if no WARN_ON dumps are triggered. Maybe we also need "get_xstats_size" for the CAN xstats. Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-06ems_usb: Fix byte order issues on big endian machinesSebastian Haas
CPC-USB is using a ARM7 core with little endian byte order. The "id" field in can_msg needs byte order conversion from/to CPU byte order. Signed-off-by: Sebastian Haas <haas@ems-wuensche.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-10-27Merge branch 'master' of ↵David S. Miller
master.kernel.org:/pub/scm/linux/kernel/git/davem/net-2.6 Conflicts: drivers/net/sh_eth.c
2009-10-27can: sja1000: fix bug using library functions for skb allocationKurt Van Dijck
Commit 7b6856a0 "can: provide library functions for skb allocation" did not properly remove two lines of the SJA1000 driver resulting in a 'skb_over_panic' when calling skb_put, as reported by Kurt. Signed-off-by: Kurt Van Dijck <kurt.van.dijck@eia.be> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-10-20can: provide library functions for skb allocationWolfgang Grandegger
This patch makes the private functions alloc_can_skb() and alloc_can_err_skb() of the at91_can driver public and adapts all drivers to use these. While making the patch I realized, that the skb's are *not* setup consistently. It's now done as shown below: skb->protocol = htons(ETH_P_CAN); skb->pkt_type = PACKET_BROADCAST; skb->ip_summed = CHECKSUM_UNNECESSARY; *cf = (struct can_frame *)skb_put(skb, sizeof(struct can_frame)); memset(*cf, 0, sizeof(struct can_frame)); The frame is zeroed out to avoid uninitialized data to be passed to user space. Some drivers or library code did not set "pkt_type" or "ip_summed". Also, "__constant_htons()" should not be used for runtime invocations, as pointed out by David Miller. Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-10-14net: Fix OF platform drivers coldplug/hotplug when compiled as modulesAnton Vorontsov
Some OF platform drivers are missing module device tables, so they won't load automatically on boot. This patch fixes the issue by adding proper MODULE_DEVICE_TABLE() macros to the drivers. Signed-off-by: Anton Vorontsov <avorontsov@ru.mvista.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-10-13can: make the number of echo skb's configurableWolfgang Grandegger
This patch allows the CAN controller driver to define the number of echo skb's used for the local loopback (echo), as suggested by Kurt Van Dijck, with the function: struct net_device *alloc_candev(int sizeof_priv, unsigned int echo_skb_max); The CAN drivers have been adapted accordingly. For the ems_usb driver, as suggested by Sebastian Haas, the number of echo skb's has been increased to 10, which improves the transmission performance a lot. Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: Kurt Van Dijck <kurt.van.dijck@eia.be> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-10-07can: add TI CAN (HECC) driverAnant Gole
TI HECC (High End CAN Controller) module is found on many TI devices. It has 32 hardware mailboxes with full implementation of CAN protocol 2.0B with bus speeds up to 1Mbps. Specifications of the module are available on TI web <http://www.ti.com> Signed-off-by: Anant Gole <anantgole@ti.com> Signed-off-by: David S. Miller <davem@davemloft.net>
2009-09-25at91_can: Forgotten git 'add' of at91_can.cDavid S. Miller
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-09-24ems_pci: fix size of CAN controllers BAR mapping for CPC-PCI v2Sebastian Haas
The driver mapped only 128 bytes of the CAN controller address space when a CPC-PCI v2 was detected (incl. CPC-104P). This patch will fix it by always mapping the whole address space (4096 bytes on all boards) of the corresponding PCI BAR. Signed-off-by: Sebastian Haas <haas@ems-wuensche.com> Signed-off-by: Wolfgang Grandegger <wg@grandegger.com> Signed-off-by: David S. Miller <davem@davemloft.net>