Age | Commit message (Collapse) | Author |
|
smatch complains that 'ret' may be returned un-initialized.
Explicitly return 0 if we reach the end of the function (should
'opp_table->clk_count' be 0).
Fixes: 8174a3a613af ("OPP: Provide a simple implementation to configure multiple clocks")
Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
git://git.kernel.org/pub/scm/linux/kernel/git/vireshk/pm
Pull operating performance points (OPP) updates for 5.20-rc1 from Viresh
Kumar:
"- Make dev_pm_opp_set_regulators() accept NULL terminated list (Viresh
Kumar).
- Add dev_pm_opp_set_config() and friends and migrate other
users/helpers to using them (Viresh Kumar).
- Add support for multiple clocks for a device (Viresh Kumar and
Krzysztof Kozlowski).
- Configure resources before adding OPP table for Venus (Stanimir
Varbanov).
- Keep reference count up for opp->np and opp_table->np while they are
still in use (Liang He).
- Minor cleanups (Viresh Kumar and Yang Li)."
* tag 'opp-updates-5.20-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/vireshk/pm: (43 commits)
venus: pm_helpers: Fix warning in OPP during probe
OPP: Don't drop opp->np reference while it is still in use
OPP: Don't drop opp_table->np reference while it is still in use
OPP: Remove dev{m}_pm_opp_of_add_table_noclk()
PM / devfreq: tegra30: Register config_clks helper
OPP: Allow config_clks helper for single clk case
OPP: Provide a simple implementation to configure multiple clocks
OPP: Assert clk_count == 1 for single clk helpers
OPP: Add key specific assert() method to key finding helpers
OPP: Compare bandwidths for all paths in _opp_compare_key()
OPP: Allow multiple clocks for a device
dt-bindings: opp: accept array of frequencies
OPP: Make dev_pm_opp_set_opp() independent of frequency
OPP: Reuse _opp_compare_key() in _opp_add_static_v2()
OPP: Remove rate_not_available parameter to _opp_add()
OPP: Use consistent names for OPP table instances
OPP: Use generic key finding helpers for bandwidth key
OPP: Use generic key finding helpers for level key
OPP: Add generic key finding helpers and use them for freq APIs
OPP: Remove dev_pm_opp_find_freq_ceil_by_volt()
...
|
|
The struct dev_pm_opp contains a reference of the DT node, opp->np,
throughout its lifetime. We should increase the refcount for the same
from _opp_add_static_v2(), and drop it while removing the OPP finally.
Signed-off-by: Liang He <windhl@126.com>
[ Viresh: Updated subject / commit log, create _of_clear_opp() and drop
reference from it]
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The OPP table contains a reference of the DT node, opp_table->np,
throughout its lifetime. We shouldn't drop the refcount for the same
from _of_init_opp_table(), but do that while removing the OPP table
finally.
Signed-off-by: Liang He <windhl@126.com>
[ Viresh: Updated subject / commit log and drop reference from
_of_clear_opp_table() ]
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The milli-Watts precision causes rounding errors while calculating
efficiency cost for each OPP. This is especially visible in the 'simple'
Energy Model (EM), where the power for each OPP is provided from OPP
framework. This can cause some OPPs to be marked inefficient, while
using micro-Watts precision that might not happen.
Update all EM users which access 'power' field and assume the value is
in milli-Watts.
Solve also an issue with potential overflow in calculation of energy
estimation on 32bit machine. It's needed now since the power value
(thus the 'cost' as well) are higher.
Example calculation which shows the rounding error and impact:
power = 'dyn-power-coeff' * volt_mV * volt_mV * freq_MHz
power_a_uW = (100 * 600mW * 600mW * 500MHz) / 10^6 = 18000
power_a_mW = (100 * 600mW * 600mW * 500MHz) / 10^9 = 18
power_b_uW = (100 * 605mW * 605mW * 600MHz) / 10^6 = 21961
power_b_mW = (100 * 605mW * 605mW * 600MHz) / 10^9 = 21
max_freq = 2000MHz
cost_a_mW = 18 * 2000MHz/500MHz = 72
cost_a_uW = 18000 * 2000MHz/500MHz = 72000
cost_b_mW = 21 * 2000MHz/600MHz = 70 // <- artificially better
cost_b_uW = 21961 * 2000MHz/600MHz = 73203
The 'cost_b_mW' (which is based on old milli-Watts) is misleadingly
better that the 'cost_b_uW' (this patch uses micro-Watts) and such
would have impact on the 'inefficient OPPs' information in the Cpufreq
framework. This patch set removes the rounding issue.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
|
|
Remove the now unused variants and the now unnecessary "getclk"
parameter from few routines.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
There is a corner case with Tegra30, where we want to skip clk
configuration via dev_pm_opp_set_opp(), but still want the OPP core to
read the "opp-hz" property so we can find the right OPP via freq finding
helpers.
This is the easiest of the ways to make it work, without any special
hacks in the OPP core. Allow config_clks to be passed for single clk
case.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
This provides a simple implementation to configure multiple clocks for a
device.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Many helpers can be safely called only for devices that have a single
clk associated with them. Assert the same for those routines.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The helpers for the clock key, at least, would need to assert that the
helpers are called only for single clock case. Prepare for that by
adding an argument to the key finding helpers.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Replicate the same behavior as "rates" here and compare all values
instead of relying on the first entry alone.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
This patch adds support to allow multiple clocks for a device.
The design is pretty much similar to how this is done for regulators,
and platforms can supply their own version of the config_clks() callback
if they have multiple clocks for their device. The core manages the
calls via opp_table->config_clks() eventually.
We have kept both "clk" and "clks" fields in the OPP table structure and
the reason is provided as a comment in _opp_set_clknames(). The same
isn't done for "rates" though and we use rates[0] at most of the places
now.
Co-developed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Tested-by: Jon Hunter <jonathanh@nvidia.com>
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Tested-by: Manivannan Sadhasivam <manivannan.sadhasivam@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
dev_pm_opp_set_opp() can be called for any device, it may or may not
have a frequency value associated with it.
If a frequency value isn't available, we pass 0 to _set_opp(). Make it
optional instead by making _set_opp() accept a pointer instead, as the
frequency value is anyway available in the OPP. This makes
dev_pm_opp_set_opp() and _set_opp() completely independent of any
special key value.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Reuse _opp_compare_key() in _opp_add_static_v2() instead of just
comparing frequency while finding suspend frequency. Also add a comment
over _opp_compare_key() explaining its return values.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
commit 32715be4fe95 ("opp: Fix adding OPP entries in a wrong order if
rate is unavailable") removed the only user of this field, get rid of
rest of it now.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The OPP table is called "opp_table" at most of the places and "table" at
few. Make all of them follow the same naming convention, "opp_table".
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Use the recently added generic key findings helpers to find bandwidth
key values.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Use the recently added generic key findings helpers to find level key
values.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
There are three type of helpers, to find exact, ceil, and floor values,
replicated for multiple key types, freq, level, bw. And all of these
helpers share a lot of boilerplate code.
Add generic key finding helpers to reduce code redundancy.
Also update the freq finder helpers to use the new infrastructure.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
This was added few years back, but the code that was supposed to use it
never got merged. Remove the unused helper.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The only user of the custom helper is migrated to use
dev_pm_opp_set_config_regulators() interface. Remove the now unused
custom OPP helper support.
This cleans up _set_opp() and leaves a single code path to be used by
all users.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The OPP core now provides dev_pm_opp_set_config_regulators() interface,
which needs the platforms to just set the OPP voltages instead of both
clk and voltage. The clock is set by the OPP core instead and hence
reduces code redundancy.
Migrate the only user of the custom set_opp() to
dev_pm_opp_set_config_regulators().
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
We already have an API for getting voltage information for a single
regulator, dev_pm_opp_get_voltage(), but there is nothing available for
multiple regulator case.
This patch adds a new API, dev_pm_opp_get_supplies(), to get all
information related to the supplies for an OPP.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
In order to reuse the same code path, i.e. clk_set_rate() from
_set_opp(), migrate _generic_set_opp_regulator() to implement a
config_regulators() interface.
It is renamed to _opp_config_regulator_single() and is set as the
preferred config_regulators() interface whenever we have a single
regulator available.
Note that this also drops code responsible for restoring the
voltage/freq in case of errors. We aren't handling that properly
currently, restoring only some of the resources while leaving others out
(like bandwidth and required OPPs). It is better to drop all of it
instead of partial restoration.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Extend the dev_pm_opp_set_config() interface to allow adding
config_regulators() helpers. This helper will be called to set the
voltages of the regulators from the regular path in _set_opp(), while we
are trying to change the OPP.
This will eventually replace the custom set_opp() helper.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Now that we have a central API to handle all OPP table configurations,
migrate the set-prop-name family of helpers to use the new
infrastructure.
The return type and parameter to the APIs change a bit due to this,
update the current users as well in the same commit in order to avoid
breaking builds.
Acked-by: Samuel Holland <samuel@sholland.org> # sun50i
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Now that we have a central API to handle all OPP table configurations,
migrate the attach-genpd family of helpers to use the new
infrastructure.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Now that we have a central API to handle all OPP table configurations,
migrate the set-opp-helper family of helpers to use the new
infrastructure.
The return type and parameter to the APIs change a bit due to this,
update the current users as well in the same commit in order to avoid
breaking builds.
Remove devm_pm_opp_register_set_opp_helper() as it has no users
currently.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Now that we have a central API to handle all OPP table configurations,
migrate the set-clk-name family of helpers to use the new
infrastructure.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Now that we have a central API to handle all OPP table configurations,
migrate the set-supported-hw family of helpers to use the new
infrastructure.
The return type and parameter to the APIs change a bit due to this,
update the current users as well in the same commit in order to avoid
breaking builds.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Now that we have a central API to handle all OPP table configurations,
migrate the set-regulators family of helpers to use the new
infrastructure.
The return type and parameter to the APIs change a bit due to this,
update the current users as well in the same commit in order to avoid
breaking builds.
Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The OPP core already have few configuration specific APIs and it is
getting complex or messy for both the OPP core and its users.
Lets introduce a new set of API which will be used for all kind of
different configurations, and shall eventually be used by all the
existing ones.
The new API, returns a unique token instead of a pointer to the OPP
table, which allows the OPP core to drop the resources selectively later
on.
Tested-by: Dmitry Osipenko <dmitry.osipenko@collabora.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Make dev_pm_opp_set_regulators() accept a NULL terminated list of names
instead of making the callers keep the two parameters in sync, which
creates an opportunity for bugs to get in.
Suggested-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Reviewed-by: Steven Price <steven.price@arm.com> # panfrost
Reviewed-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Track if the clock name is configured by the platform or not. This is a
preparatory change and will be used by later commits. This also makes
the behavior of the clkname API similar to other ones, which allow
repeated calls to the same API for each CPU.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Replace rate with state.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Make @freq to @bw in dev_pm_opp_find_bw_ceil() and
dev_pm_opp_find_bw_floor() kernel-doc comment to
remove warnings found by running scripts/kernel-doc,
which is caused by using 'make W=1'.
drivers/opp/core.c:753: warning: Function parameter or member 'bw' not
described in 'dev_pm_opp_find_bw_ceil'
drivers/opp/core.c:753: warning: Excess function parameter 'freq'
description in 'dev_pm_opp_find_bw_ceil'
drivers/opp/core.c:812: warning: Function parameter or member 'bw' not
described in 'dev_pm_opp_find_bw_floor'
drivers/opp/core.c:812: warning: Excess function parameter 'freq'
description in 'dev_pm_opp_find_bw_floor'
Reported-by: Abaci Robot <abaci@linux.alibaba.com>
Signed-off-by: Yang Li <yang.lee@linux.alibaba.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
dev_pm_domain_attach_by_name() may return NULL in some cases,
so IS_ERR() doesn't meet the requirements. Thus fix it.
Fixes: 6319aee10e53 ("opp: Attach genpds to devices from within OPP core")
Signed-off-by: Tang Bin <tangbin@cmss.chinamobile.com>
[ Viresh: Replace ENODATA with ENODEV ]
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
git://git.kernel.org/pub/scm/linux/kernel/git/vireshk/pm
Pull OPP (Operating Performance Points) updates for 5.19-rc1 from Viresh
Kumar:
- Minor update to dt-binding for Qcom's opp-v2-kryo-cpu (Yassine
Oudjana).
- Use list iterator only inside the list_for_each_entry loop (Xiaomeng
Tong, and Jakob Koschel).
- New APIs related to finding OPP based on interconnect bandwidth
(Krzysztof Kozlowski).
- Fix the missing of_node_put() in _bandwidth_supported() (Dan
Carpenter).
- Cleanups (Krzysztof Kozlowski, and Viresh Kumar).
* tag 'opp-updates-5.19-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/vireshk/pm:
opp: Reorder definition of ceil/floor helpers
opp: Add apis to retrieve opps with interconnect bandwidth
dt-bindings: opp: opp-v2-kryo-cpu: Remove SMEM
opp: use list iterator only inside the loop
opp: replace usage of found with dedicated list iterator variable
PM: opp: simplify with dev_err_probe()
OPP: call of_node_put() on error path in _bandwidth_supported()
|
|
Reorder the helpers to keep all freq specific ones, followed by level
and bw.
No functional change.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Add dev_pm_opp_find_bw_ceil and dev_pm_opp_find_bw_floor to retrieve opps
based on interconnect associated with the opp and bandwidth. The index
variable is the index of the interconnect as specified in the opp table
in Devicetree.
Co-developed-by: Thara Gopinath <thara.gopinath@linaro.org>
Signed-off-by: Thara Gopinath <thara.gopinath@linaro.org>
Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The .active_power() callback passes the device pointer when it's called.
Aligned with a convetion present in other subsystems and pass the 'dev'
as a first argument. It looks more cleaner.
Adjust all affected drivers which implement that API callback.
Suggested-by: Ionela Voinescu <ionela.voinescu@arm.com>
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Reviewed-by: Ionela Voinescu <ionela.voinescu@arm.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
|
|
To move the list iterator variable into the list_for_each_entry_*()
macro in the future it should be avoided to use the list iterator
variable after the loop body.
To *never* use the list iterator variable after the loop it was
concluded to use a separate dedicated pointer variable [1].
In this case, use a new variable 'iter' as the list iterator, while
use the old variable 'new_dev' as a dedicated pointer to point to the
found entry. And BUG_ON(!new_dev);.
[1]: https://lore.kernel.org/all/CAHk-=wgRr_D8CB-D9Kg-c=EHreAsk5SqXPwr9Y7k9sA6cWXJ6w@mail.gmail.com/
Signed-off-by: Xiaomeng Tong <xiam0nd.tong@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
To move the list iterator variable into the list_for_each_entry_*()
macro in the future it should be avoided to use the list iterator
variable after the loop body.
To *never* use the list iterator variable after the loop it was
concluded to use a separate iterator variable instead of a
found boolean [1].
This removes the need to use a found variable and simply checking if
the variable was set, can determine if the break/goto was hit.
Link: https://lore.kernel.org/all/CAHk-=wgRr_D8CB-D9Kg-c=EHreAsk5SqXPwr9Y7k9sA6cWXJ6w@mail.gmail.com/
Signed-off-by: Jakob Koschel <jakobkoschel@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Common pattern of handling deferred probe can be simplified with
dev_err_probe(). Less code and the error value gets printed.
Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
This code does not call of_node_put(opp_np) if of_get_next_available_child()
returns NULL. But it should.
Fixes: 45679f9b508f ("opp: Don't parse icc paths unnecessarily")
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
The Energy Model (EM) can be created based on DT entry:
'dynamic-power-coefficient'. It's a 'simple' EM which is limited to the
dynamic power. It has to fit into the math formula which requires also
information about voltage. Some of the platforms don't expose voltage
information, thus it's not possible to use EM registration using DT.
This patch aims to fix it. It introduces new implementation of the EM
registration callback. The new mechanism relies on the new OPP feature
allowing to get power (which is coming from "opp-microwatt" DT property)
expressed in micro-Watts.
The patch also opens new opportunity to better support platforms, which
have a decent static power. It allows to register the EM based on real
power measurements which models total power (static + dynamic), so better
reflects real HW.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Add new property to the OPP: power value. The OPP entry in the DT can have
"opp-microwatt". Add the needed code to handle this new property in the
existing infrastructure.
Signed-off-by: Lukasz Luba <lukasz.luba@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
It is difficult to find which OPPs are active at the moment, specially
if there are multiple OPPs with same frequency available in the device
tree (controlled by supported hardware feature).
Expose name of the DT node to find out the exact OPP.
While at it, also expose level field.
Reported-by: Leo Yan <leo.yan@linaro.org>
Tested-by: Leo Yan <leo.yan@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Fix sparse warning:
drivers/opp/of.c:924 _opp_add_static_v2() warn: passing zero to 'ERR_PTR'
For duplicate OPPs 'ret' be set to zero.
Fixes: deac8703da5f ("PM / OPP: _of_add_opp_table_v2(): increment count only if OPP is added")
Signed-off-by: YueHaibing <yuehaibing@huawei.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|
|
Add resource-managed variants of dev_pm_opp_of_add_table_indexed() and
dev_pm_opp_of_add_table_noclk(), allowing drivers to remove boilerplate
code.
Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
[ Viresh: Added underscore to devm_of_add_table_indexed() ]
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
|