adp5061_get_battery_status() only defined show chg_status <= 4, others will
be show as '-1731902199' from /sys/class/power_supply/xx/capacity_level.
switch to show them as 'Unknown'.
Signed-off-by: Wei Yongjun <weiyongjun1@huawei.com>
Acked-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
ADP5061_CHG_STATUS_1_CHG_STATUS is masked with 0x07, which means a length
of 8, but adp5061_chg_type array size is 4, may end up reading 4 elements
beyond the end of the adp5061_chg_type[] array.
Signed-off-by: Wei Yongjun <weiyongjun1@huawei.com>
Acked-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
|
|
Based on 1 normalized pattern(s):
licensed under the gpl 2
extracted by the scancode license scanner the SPDX license identifier
GPL-2.0-only
has been chosen to replace the boilerplate/reference in 135 file(s).
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Allison Randal <allison@lohutok.net>
Reviewed-by: Richard Fontana <rfontana@redhat.com>
Reviewed-by: Alexios Zavras <alexios.zavras@intel.com>
Reviewed-by: Steve Winslow <swinslow@gmail.com>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190528170026.071193225@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
|
|
We end up reading one element beyond the end of the adp5061_vmax[] array
here.
Fixes: fe8e81b7e899 ("adp5061: New driver for ADP5061 I2C battery charger")
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
|
|
This patch adds basic support for Analog Devices I2C programmable linear
battery charger.
With this driver, some parameters can be read and configured such as:
* trickle charge current level (PRECHARGE_CURRENT)
* trickle charge voltage threshold (VOLTAGE_MIN)
* weak charge threshold (VOLTAGE_AVG)
* constant current (CONSTANT_CHARGE_CURRENT)
* constant charge voltage limit (CONSTANT_CHARGE_VOLTAGE_MAX)
* battery full (CAPACITY_LEVEL)
* input current limit (INPUT_CURRENT_LIMIT)
* charger status (STATUS)
* battery status (CAPACITY_LEVEL)
* termination current (CHARGE_TERM_CURRENT)
Datasheet:
http://www.analog.com/media/en/technical-documentation/data-sheets/ADP5061.pdf
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
|