From 6f1891d01956cad406d2af8ed2e9cef6108bfc5e Mon Sep 17 00:00:00 2001 From: Benjamin Tissoires Date: Wed, 19 Jun 2013 17:49:05 +0200 Subject: HID: fix false positive out of range values Commit 6da7066906e977d42104a859c490f5f9a300488c introduced in 3.3 "HID: ignore absolute values which don't fit between logical min and max" prevents some Posiflex touch screen to work because they do not provide logical min and max for their buttons. Thus, logical min and max are at 0, discarding the buttons events, and preventing the device to report appropriate X Y. Adding a check on "min < max" solves the problem. Reported-by: Jan Kandziora Tested-by: Jan Kandziora Signed-off-by: Benjamin Tissoires Signed-off-by: Jiri Kosina --- drivers/hid/hid-input.c | 1 + 1 file changed, 1 insertion(+) (limited to 'drivers/hid') diff --git a/drivers/hid/hid-input.c b/drivers/hid/hid-input.c index 945b8158ec4c..82130cf724e4 100644 --- a/drivers/hid/hid-input.c +++ b/drivers/hid/hid-input.c @@ -1045,6 +1045,7 @@ void hidinput_hid_event(struct hid_device *hid, struct hid_field *field, struct * section 5.10 and 6.2.25 */ if ((field->flags & HID_MAIN_ITEM_VARIABLE) && + (field->logical_minimum < field->logical_maximum) && (value < field->logical_minimum || value > field->logical_maximum)) { dbg_hid("Ignoring out-of-range value %x\n", value); -- cgit v1.2.3