aboutsummaryrefslogtreecommitdiff
path: root/Documentation/networking/dsa/dsa.txt
blob: 63912ef346069b228b984c2f2d1a70f0c9c6ffc0 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
Distributed Switch Architecture
===============================

Introduction
============

This document describes the Distributed Switch Architecture (DSA) subsystem
design principles, limitations, interactions with other subsystems, and how to
develop drivers for this subsystem as well as a TODO for developers interested
in joining the effort.

Design principles
=================

The Distributed Switch Architecture is a subsystem which was primarily designed
to support Marvell Ethernet switches (MV88E6xxx, a.k.a Linkstreet product line)
using Linux, but has since evolved to support other vendors as well.

The original philosophy behind this design was to be able to use unmodified
Linux tools such as bridge, iproute2, ifconfig to work transparently whether
they configured/queried a switch port network device or a regular network
device.

An Ethernet switch is typically comprised of multiple front-panel ports, and one
or more CPU or management port. The DSA subsystem currently relies on the
presence of a management port connected to an Ethernet controller capable of
receiving Ethernet frames from the switch. This is a very common setup for all
kinds of Ethernet switches found in Small Home and Office products: routers,
gateways, or even top-of-the rack switches. This host Ethernet controller will
be later referred to as "master" and "cpu" in DSA terminology and code.

The D in DSA stands for Distributed, because the subsystem has been designed
with the ability to configure and manage cascaded switches on top of each other
using upstream and downstream Ethernet links between switches. These specific
ports are referred to as "dsa" ports in DSA terminology and code. A collection
of multiple switches connected to each other is called a "switch tree".

For each front-panel port, DSA will create specialized network devices which are
used as controlling and data-flowing endpoints for use by the Linux networking
stack. These specialized network interfaces are referred to as "slave" network
interfaces in DSA terminology and code.

The ideal case for using DSA is when an Ethernet switch supports a "switch tag"
which is a hardware feature making the switch insert a specific tag for each
Ethernet frames it received to/from specific ports to help the management
interface figure out:

- what port is this frame coming from
- what was the reason why this frame got forwarded
- how to send CPU originated traffic to specific ports

The subsystem does support switches not capable of inserting/stripping tags, but
the features might be slightly limited in that case (traffic separation relies
on Port-based VLAN IDs).

Note that DSA does not currently create network interfaces for the "cpu" and
"dsa" ports because:

- the "cpu" port is the Ethernet switch facing side of the management
  controller, and as such, would create a duplication of feature, since you
  would get two interfaces for the same conduit: master netdev, and "cpu" netdev

- the "dsa" port(s) are just conduits between two or more switches, and as such
  cannot really be used as proper network interfaces either, only the
  downstream, or the top-most upstream interface makes sense with that model

Switch tagging protocols
------------------------

DSA currently supports 5 different tagging protocols, and a tag-less mode as
well. The different protocols are implemented in:

net/dsa/tag_trailer.c: Marvell's 4 trailer tag mode (legacy)
net/dsa/tag_dsa.c: Marvell's original DSA tag
net/dsa/tag_edsa.c: Marvell's enhanced DSA tag
net/dsa/tag_brcm.c: Broadcom's 4 bytes tag
net/dsa/tag_qca.c: Qualcomm's 2 bytes tag

The exact format of the tag protocol is vendor specific, but in general, they
all contain something which:

- identifies which port the Ethernet frame came from/should be sent to
- provides a reason why this frame was forwarded to the management interface

Master network devices
----------------------

Master network devices are regular, unmodified Linux network device drivers for
the CPU/management Ethernet interface. Such a driver might occasionally need to
know whether DSA is enabled (e.g.: to enable/disable specific offload features),
but the DSA subsystem has been proven to work with industry standard drivers:
e1000e, mv643xx_eth etc. without having to introduce modifications to these
drivers. Such network devices are also often referred to as conduit network
devices since they act as a pipe between the host processor and the hardware
Ethernet switch.

Networking stack hooks
----------------------

When a master netdev is used with DSA, a small hook is placed in in the
networking stack is in order to have the DSA subsystem process the Ethernet
switch specific tagging protocol. DSA accomplishes this by registering a
specific (and fake) Ethernet type (later becoming skb->protocol) with the
networking stack, this is also known as a ptype or packet_type. A typical
Ethernet Frame receive sequence looks like this:

Master network device (e.g.: e1000e):

Receive interrupt fires:
- receive function is invoked
- basic packet processing is done: getting length, status etc.
- packet is prepared to be processed by the Ethernet layer by calling
  eth_type_trans

net/ethernet/eth.c:

eth_type_trans(skb, dev)
	if (dev->dsa_ptr != NULL)
		-> skb->protocol = ETH_P_XDSA

drivers/net/ethernet/*:

netif_receive_skb(skb)
	-> iterate over registered packet_type
		-> invoke handler for ETH_P_XDSA, calls dsa_switch_rcv()

net/dsa/dsa.c:
	-> dsa_switch_rcv()
		-> invoke switch tag specific protocol handler in
		   net/dsa/tag_*.c

net/dsa/tag_*.c:
	-> inspect and strip switch tag protocol to determine originating port
	-> locate per-port network device
	-> invoke eth_type_trans() with the DSA slave network device
	-> invoked netif_receive_skb()

Past this point, the DSA slave network devices get delivered regular Ethernet
frames that can be processed by the networking stack.

Slave network devices
---------------------

Slave network devices created by DSA are stacked on top of their master network
device, each of these network interfaces will be responsible for being a
controlling and data-flowing end-point for each front-panel port of the switch.
These interfaces are specialized in order to:

- insert/remove the switch tag protocol (if it exists) when sending traffic
  to/from specific switch ports
- query the switch for ethtool operations: statistics, link state,
  Wake-on-LAN, register dumps...
- external/internal PHY management: link, auto-negotiation etc.

These slave network devices have custom net_device_ops and ethtool_ops function
pointers which allow DSA to introduce a level of layering between the networking
stack/ethtool, and the switch driver implementation.

Upon frame transmission from these slave network devices, DSA will look up which
switch tagging protocol is currently registered with these network devices, and
invoke a specific transmit routine which takes care of adding the relevant
switch tag in the Ethernet frames.

These frames are then queued for transmission using the master network device
ndo_start_xmit() function, since they contain the appropriate switch tag, the
Ethernet switch will be able to process these incoming frames from the
management interface and delivers these frames to the physical switch port.

Graphical representation
------------------------

Summarized, this is basically how DSA looks like from a network device
perspective:


			|---------------------------
			| CPU network device (eth0)|
			----------------------------
			| <tag added by switch     |
			|                          |
			|                          |
			|        tag added by CPU> |
		|--------------------------------------------|
		| Switch driver				     |
		|--------------------------------------------|
                    ||        ||         ||
		|-------|  |-------|  |-------|
		| sw0p0 |  | sw0p1 |  | sw0p2 |
		|-------|  |-------|  |-------|

Slave MDIO bus
--------------

In order to be able to read to/from a switch PHY built into it, DSA creates a
slave MDIO bus which allows a specific switch driver to divert and intercept
MDIO reads/writes towards specific PHY addresses. In most MDIO-connected
switches, these functions would utilize direct or indirect PHY addressing mode
to return standard MII registers from the switch builtin PHYs, allowing the PHY
library and/or to return link status, link partner pages, auto-negotiation
results etc..

For Ethernet switches which have both external and internal MDIO busses, the
slave MII bus can be utilized to mux/demux MDIO reads and writes towards either
internal or external MDIO devices this switch might be connected to: internal
PHYs, external PHYs, or even external switches.

Data structures
---------------

DSA data structures are defined in include/net/dsa.h as well as
net/dsa/dsa_priv.h.

dsa_chip_data: platform data configuration for a given switch device, this
structure describes a switch device's parent device, its address, as well as
various properties of its ports: names/labels, and finally a routing table
indication (when cascading switches)

dsa_platform_data: platform device configuration data which can reference a
collection of dsa_chip_data structure if multiples switches are cascaded, the
master network device this switch tree is attached to needs to be referenced

dsa_switch_tree: structure assigned to the master network device under
"dsa_ptr", this structure references a dsa_platform_data structure as well as
the tagging protocol supported by the switch tree, and which receive/transmit
function hooks should be invoked, information about the directly attached switch
is also provided: CPU port. Finally, a collection of dsa_switch are referenced
to address individual switches in the tree.

dsa_switch: structure describing a switch device in the tree, referencing a
dsa_switch_tree as a backpointer, slave network devices, master network device,
and a reference to the backing dsa_switch_ops

dsa_switch_ops: structure referencing function pointers, see below for a full
description.

Design limitations
==================

DSA is a platform device driver
-------------------------------

DSA is implemented as a DSA platform device driver which is convenient because
it will register the entire DSA switch tree attached to a master network device
in one-shot, facilitating the device creation and simplifying the device driver
model a bit, this comes however with a number of limitations:

- building DSA and its switch drivers as modules is currently not working
- the device driver parenting does not necessarily reflect the original
  bus/device the switch can be created from
- supporting non-MDIO and non-MMIO (platform) switches is not possible

Limits on the number of devices and ports
-----------------------------------------

DSA currently limits the number of maximum switches within a tree to 4
(DSA_MAX_SWITCHES), and the number of ports per switch to 12 (DSA_MAX_PORTS).
These limits could be extended to support larger configurations would this need
arise.

Lack of CPU/DSA network devices
-------------------------------

DSA does not currently create slave network devices for the CPU or DSA ports, as
described before. This might be an issue in the following cases:

- inability to fetch switch CPU port statistics counters using ethtool, which
  can make it harder to debug MDIO switch connected using xMII interfaces

- inability to configure the CPU port link parameters based on the Ethernet
  controller capabilities attached to it: http://patchwork.ozlabs.org/patch/509806/

- inability to configure specific VLAN IDs / trunking VLANs between switches
  when using a cascaded setup

Common pitfalls using DSA setups
--------------------------------

Once a master network device is configured to use DSA (dev->dsa_ptr becomes
non-NULL), and the switch behind it expects a tagging protocol, this network
interface can only exclusively be used as a conduit interface. Sending packets
directly through this interface (e.g.: opening a socket using this interface)
will not make us go through the switch tagging protocol transmit function, so
the Ethernet switch on the other end, expecting a tag will typically drop this
frame.

Slave network devices check that the master network device is UP before allowing
you to administratively bring UP these slave network devices. A common
configuration mistake is forgetting to bring UP the master network device first.

Interactions with other subsystems
==================================

DSA currently leverages the following subsystems:

- MDIO/PHY library: drivers/net/phy/phy.c, mdio_bus.c
- Switchdev: net/switchdev/*
- Device Tree for various of_* functions
- HWMON: drivers/hwmon/*

MDIO/PHY library
----------------

Slave network devices exposed by DSA may or may not be interfacing with PHY
devices (struct phy_device as defined in include/linux/phy.h), but the DSA
subsystem deals with all possible combinations:

- internal PHY devices, built into the Ethernet switch hardware
- external PHY devices, connected via an internal or external MDIO bus
- internal PHY devices, connected via an internal MDIO bus
- special, non-autonegotiated or non MDIO-managed PHY devices: SFPs, MoCA; a.k.a
  fixed PHYs

The PHY configuration is done by the dsa_slave_phy_setup() function and the
logic basically looks like this:

- if Device Tree is used, the PHY device is looked up using the standard
  "phy-handle" property, if found, this PHY device is created and registered
  using of_phy_connect()

- if Device Tree is used, and the PHY device is "fixed", that is, conforms to
  the definition of a non-MDIO managed PHY as defined in
  Documentation/devicetree/bindings/net/fixed-link.txt, the PHY is registered
  and connected transparently using the special fixed MDIO bus driver

- finally, if the PHY is built into the switch, as is very common with
  standalone switch packages, the PHY is probed using the slave MII bus created
  by DSA


SWITCHDEV
---------

DSA directly utilizes SWITCHDEV when interfacing with the bridge layer, and
more specifically with its VLAN filtering portion when configuring VLANs on top
of per-port slave network devices. Since DSA primarily deals with
MDIO-connected switches, although not exclusively, SWITCHDEV's
prepare/abort/commit phases are often simplified into a prepare phase which
checks whether the operation is supported by the DSA switch driver, and a commit
phase which applies the changes.

As of today, the only SWITCHDEV objects supported by DSA are the FDB and VLAN
objects.

Device Tree
-----------

DSA features a standardized binding which is documented in
Documentation/devicetree/bindings/net/dsa/dsa.txt. PHY/MDIO library helper
functions such as of_get_phy_mode(), of_phy_connect() are also used to query
per-port PHY specific details: interface connection, MDIO bus location etc..

HWMON
-----

Some switch drivers feature internal temperature sensors which are exposed as
regular HWMON devices in /sys/class/hwmon/.

Driver development
==================

DSA switch drivers need to implement a dsa_switch_ops structure which will
contain the various members described below.

register_switch_driver() registers this dsa_switch_ops in its internal list
of drivers to probe for. unregister_switch_driver() does the exact opposite.

Unless requested differently by setting the priv_size member accordingly, DSA
does not allocate any driver private context space.

Switch configuration
--------------------

- tag_protocol: this is to indicate what kind of tagging protocol is supported,
  should be a valid value from the dsa_tag_protocol enum

- probe: probe routine which will be invoked by the DSA platform device upon
  registration to test for the presence/absence of a switch device. For MDIO
  devices, it is recommended to issue a read towards internal registers using
  the switch pseudo-PHY and return whether this is a supported device. For other
  buses, return a non-NULL string

- setup: setup function for the switch, this function is responsible for setting
  up the dsa_switch_ops private structure with all it needs: register maps,
  interrupts, mutexes, locks etc.. This function is also expected to properly
  configure the switch to separate all network interfaces from each other, that
  is, they should be isolated by the switch hardware itself, typically by creating
  a Port-based VLAN ID for each port and allowing only the CPU port and the
  specific port to be in the forwarding vector. Ports that are unused by the
  platform should be disabled. Past this function, the switch is expected to be
  fully configured and ready to serve any kind of request. It is recommended
  to issue a software reset of the switch during this setup function in order to
  avoid relying on what a previous software agent such as a bootloader/firmware
  may have previously configured.

- set_addr: Some switches require the programming of the management interface's
  Ethernet MAC address, switch drivers can also disable ageing of MAC addresses
  on the management interface and "hardcode"/"force" this MAC address for the
  CPU/management interface as an optimization

PHY devices and link management
-------------------------------

- get_phy_flags: Some switches are interfaced to various kinds of Ethernet PHYs,
  if the PHY library PHY driver needs to know about information it cannot obtain
  on its own (e.g.: coming from switch memory mapped registers), this function
  should return a 32-bits bitmask of "flags", that is private between the switch
  driver and the Ethernet PHY driver in drivers/net/phy/*.

- phy_read: Function invoked by the DSA slave MDIO bus when attempting to read
  the switch port MDIO registers. If unavailable, return 0xffff for each read.
  For builtin switch Ethernet PHYs, this function should allow reading the link
  status, auto-negotiation results, link partner pages etc..

- phy_write: Function invoked by the DSA slave MDIO bus when attempting to write
  to the switch port MDIO registers. If unavailable return a negative error
  code.

- adjust_link: Function invoked by the PHY library when a slave network device
  is attached to a PHY device. This function is responsible for appropriately
  configuring the switch port link parameters: speed, duplex, pause based on
  what the phy_device is providing.

- fixed_link_update: Function invoked by the PHY library, and specifically by
  the fixed PHY driver asking the switch driver for link parameters that could
  not be auto-negotiated, or obtained by reading the PHY registers through MDIO.
  This is particularly useful for specific kinds of hardware such as QSGMII,
  MoCA or other kinds of non-MDIO managed PHYs where out of band link
  information is obtained

Ethtool operations
------------------

- get_strings: ethtool function used to query the driver's strings, will
  typically return statistics strings, private flags strings etc.

- get_ethtool_stats: ethtool function used to query per-port statistics and
  return their values. DSA overlays slave network devices general statistics:
  RX/TX counters from the network device, with switch driver specific statistics
  per port

- get_sset_count: ethtool function used to query the number of statistics items

- get_wol: ethtool function used to obtain Wake-on-LAN settings per-port, this
  function may, for certain implementations also query the master network device
  Wake-on-LAN settings if this interface needs to participate in Wake-on-LAN

- set_wol: ethtool function used to configure Wake-on-LAN settings per-port,
  direct counterpart to set_wol with similar restrictions

- set_eee: ethtool function which is used to configure a switch port EEE (Green
  Ethernet) settings, can optionally invoke the PHY library to enable EEE at the
  PHY level if relevant. This function should enable EEE at the switch port MAC
  controller and data-processing logic

- get_eee: ethtool function which is used to query a switch port EEE settings,
  this function should return the EEE state of the switch port MAC controller
  and data-processing logic as well as query the PHY for its currently configured
  EEE settings

- get_eeprom_len: ethtool function returning for a given switch the EEPROM
  length/size in bytes

- get_eeprom: ethtool function returning for a given switch the EEPROM contents

- set_eeprom: ethtool function writing specified data to a given switch EEPROM

- get_regs_len: ethtool function returning the register length for a given
  switch

- get_regs: ethtool function returning the Ethernet switch internal register
  contents. This function might require user-land code in ethtool to
  pretty-print register values and registers

Power management
----------------

- suspend: function invoked by the DSA platform device when the system goes to
  suspend, should quiesce all Ethernet switch activities, but keep ports
  participating in Wake-on-LAN active as well as additional wake-up logic if
  supported

- resume: function invoked by the DSA platform device when the system resumes,
  should resume all Ethernet switch activities and re-configure the switch to be
  in a fully active state

- port_enable: function invoked by the DSA slave network device ndo_open
  function when a port is administratively brought up, this function should be
  fully enabling a given switch port. DSA takes care of marking the port with
  BR_STATE_BLOCKING if the port is a bridge member, or BR_STATE_FORWARDING if it
  was not, and propagating these changes down to the hardware

- port_disable: function invoked by the DSA slave network device ndo_close
  function when a port is administratively brought down, this function should be
  fully disabling a given switch port. DSA takes care of marking the port with
  BR_STATE_DISABLED and propagating changes to the hardware if this port is
  disabled while being a bridge member

Hardware monitoring
-------------------

These callbacks are only available if CONFIG_NET_DSA_HWMON is enabled:

- get_temp: this function queries the given switch for its temperature

- get_temp_limit: this function returns the switch current maximum temperature
  limit

- set_temp_limit: this function configures the maximum temperature limit allowed

- get_temp_alarm: this function returns the critical temperature threshold
  returning an alarm notification

See Documentation/hwmon/sysfs-interface for details.

Bridge layer
------------

- port_bridge_join: bridge layer function invoked when a given switch port is
  added to a bridge, this function should be doing the necessary at the switch
  level to permit the joining port from being added to the relevant logical
  domain for it to ingress/egress traffic with other members of the bridge.

- port_bridge_leave: bridge layer function invoked when a given switch port is
  removed from a bridge, this function should be doing the necessary at the
  switch level to deny the leaving port from ingress/egress traffic from the
  remaining bridge members. When the port leaves the bridge, it should be aged
  out at the switch hardware for the switch to (re) learn MAC addresses behind
  this port.

- port_stp_state_set: bridge layer function invoked when a given switch port STP
  state is computed by the bridge layer and should be propagated to switch
  hardware to forward/block/learn traffic. The switch driver is responsible for
  computing a STP state change based on current and asked parameters and perform
  the relevant ageing based on the intersection results

Bridge VLAN filtering
---------------------

- port_vlan_filtering: bridge layer function invoked when the bridge gets
  configured for turning on or off VLAN filtering. If nothing specific needs to
  be done at the hardware level, this callback does not need to be implemented.
  When VLAN filtering is turned on, the hardware must be programmed with
  rejecting 802.1Q frames which have VLAN IDs outside of the programmed allowed
  VLAN ID map/rules.  If there is no PVID programmed into the switch port,
  untagged frames must be rejected as well. When turned off the switch must
  accept any 802.1Q frames irrespective of their VLAN ID, and untagged frames are
  allowed.

- port_vlan_prepare: bridge layer function invoked when the bridge prepares the
  configuration of a VLAN on the given port. If the operation is not supported
  by the hardware, this function should return -EOPNOTSUPP to inform the bridge
  code to fallback to a software implementation. No hardware setup must be done
  in this function. See port_vlan_add for this and details.

- port_vlan_add: bridge layer function invoked when a VLAN is configured
  (tagged or untagged) for the given switch port

- port_vlan_del: bridge layer function invoked when a VLAN is removed from the
  given switch port

- port_vlan_dump: bridge layer function invoked with a switchdev callback
  function that the driver has to call for each VLAN the given port is a member
  of. A switchdev object is used to carry the VID and bridge flags.

- port_fdb_prepare: bridge layer function invoked when the bridge prepares the
  installation of a Forwarding Database entry. If the operation is not
  supported, this function should return -EOPNOTSUPP to inform the bridge code
  to fallback to a software implementation. No hardware setup must be done in
  this function. See port_fdb_add for this and details.

- port_fdb_add: bridge layer function invoked when the bridge wants to install a
  Forwarding Database entry, the switch hardware should be programmed with the
  specified address in the specified VLAN Id in the forwarding database
  associated with this VLAN ID

Note: VLAN ID 0 corresponds to the port private database, which, in the context
of DSA, would be the its port-based VLAN, used by the associated bridge device.

- port_fdb_del: bridge layer function invoked when the bridge wants to remove a
  Forwarding Database entry, the switch hardware should be programmed to delete
  the specified MAC address from the specified VLAN ID if it was mapped into
  this port forwarding database

- port_fdb_dump: bridge layer function invoked with a switchdev callback
  function that the driver has to call for each MAC address known to be behind
  the given port. A switchdev object is used to carry the VID and FDB info.

- port_mdb_prepare: bridge layer function invoked when the bridge prepares the
  installation of a multicast database entry. If the operation is not supported,
  this function should return -EOPNOTSUPP to inform the bridge code to fallback
  to a software implementation. No hardware setup must be done in this function.
  See port_fdb_add for this and details.

- port_mdb_add: bridge layer function invoked when the bridge wants to install
  a multicast database entry, the switch hardware should be programmed with the
  specified address in the specified VLAN ID in the forwarding database
  associated with this VLAN ID.

Note: VLAN ID 0 corresponds to the port private database, which, in the context
of DSA, would be the its port-based VLAN, used by the associated bridge device.

- port_mdb_del: bridge layer function invoked when the bridge wants to remove a
  multicast database entry, the switch hardware should be programmed to delete
  the specified MAC address from the specified VLAN ID if it was mapped into
  this port forwarding database.

- port_mdb_dump: bridge layer function invoked with a switchdev callback
  function that the driver has to call for each MAC address known to be behind
  the given port. A switchdev object is used to carry the VID and MDB info.

TODO
====

Making SWITCHDEV and DSA converge towards an unified codebase
-------------------------------------------------------------

SWITCHDEV properly takes care of abstracting the networking stack with offload
capable hardware, but does not enforce a strict switch device driver model. On
the other DSA enforces a fairly strict device driver model, and deals with most
of the switch specific. At some point we should envision a merger between these
two subsystems and get the best of both worlds.

Other hanging fruits
--------------------

- making the number of ports fully dynamic and not dependent on DSA_MAX_PORTS
- allowing more than one CPU/management interface:
  http://comments.gmane.org/gmane.linux.network/365657
- porting more drivers from other vendors:
  http://comments.gmane.org/gmane.linux.network/365510