diff options
author | Guenter Roeck | 2020-07-14 14:31:11 -0700 |
---|---|---|
committer | Guenter Roeck | 2020-07-14 14:38:50 -0700 |
commit | 8a03746c8baf82e1616f05a1a716d34378dcf780 (patch) | |
tree | 687290dc42fbde381eedff3d62b9ee1be347022d /drivers/hwmon | |
parent | 6d1d41c075a1a54ba03370e268171fec20e06563 (diff) |
hwmon: (nct6775) Accept PECI Calibration as temperature source for NCT6798D
Stefan Dietrich reports invalid temperature source messages on Asus Formula
XII Z490.
nct6775 nct6775.656: Invalid temperature source 28 at index 0,
source register 0x100, temp register 0x73
Debugging suggests that temperature source 28 reports the CPU temperature.
Let's assume that temperature sources 28 and 29 reflect "PECI Agent {0,1}
Calibration", similar to other chips of the series.
Reported-by: Stefan Dietrich <roots@gmx.de>
Cc: Stefan Dietrich <roots@gmx.de>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'drivers/hwmon')
-rw-r--r-- | drivers/hwmon/nct6775.c | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/drivers/hwmon/nct6775.c b/drivers/hwmon/nct6775.c index e7e1ddc1d631..750b08713dee 100644 --- a/drivers/hwmon/nct6775.c +++ b/drivers/hwmon/nct6775.c @@ -786,13 +786,13 @@ static const char *const nct6798_temp_label[] = { "Agent1 Dimm1", "BYTE_TEMP0", "BYTE_TEMP1", - "", - "", + "PECI Agent 0 Calibration", /* undocumented */ + "PECI Agent 1 Calibration", /* undocumented */ "", "Virtual_TEMP" }; -#define NCT6798_TEMP_MASK 0x8fff0ffe +#define NCT6798_TEMP_MASK 0xbfff0ffe #define NCT6798_VIRT_TEMP_MASK 0x80000c00 /* NCT6102D/NCT6106D specific data */ |