aboutsummaryrefslogtreecommitdiff
path: root/drivers/thermal
AgeCommit message (Collapse)Author
2020-05-22thermal: imx_scu_thermal: prevent boot hang with zero pdataAnatolij Gustschin
Should initialization of pdata values have failed for some reason, we end up in endless loop when getting the CPU temperature value and can not boot. Check alert value in pdata and only retry reading temperature if alert value is not zero. Also shorten the temperature info string. Signed-off-by: Anatolij Gustschin <agust@denx.de>
2020-05-18common: Drop linux/delay.h from common headerSimon Glass
Move this uncommon header out of the common header. Signed-off-by: Simon Glass <sjg@chromium.org>
2020-05-18common: Drop log.h from common headerSimon Glass
Move this header out of the common header. Signed-off-by: Simon Glass <sjg@chromium.org>
2020-05-18common: Drop image.h from common headerSimon Glass
Move this uncommon header out of the common header. Signed-off-by: Simon Glass <sjg@chromium.org>
2020-05-10thermal: imx_tmu: support i.MX8MPPeng Fan
Support i.MX8MP thermal which has two probes and supports temperature range from -40 to 125. Still uses default 1p HW calibration at 25C and loads calibration parameters from fuse. Signed-off-by: Ye Li <ye.li@nxp.com> Signed-off-by: Peng Fan <peng.fan@nxp.com>
2020-05-10thermal: imx_tmu: Check the TEMP range for iMX8MMPeng Fan
On iMX8MM, the V flag in TRISTR register only reflect the state of SNSR value, not the calibrated TEMP value. So checking this flag is not reliable. Per IC suggestion, change to read the TEMP/AVG_TEMP directly and check whether it in valid range 10-125C. Signed-off-by: Ye Li <ye.li@nxp.com> Signed-off-by: Peng Fan <peng.fan@nxp.com>
2020-05-10thermal: imx_tmu: Fix for temperature out of rangePeng Fan
When the temperature is out of sensor's range, the Valid bit won't be set in TRITSR register. So the polling loop won't go out. Change the codes to retry 10 times with 100ms interval for the Valid bit. If the timeout, we give a warning for the invalid data. Modifed from Ye's NXP patch Signed-off-by: Peng Fan <peng.fan@nxp.com>
2020-05-10thermal: imx_tmu: support TMU arch level initializationPeng Fan
i.MX8MM TMU needs to load some registers from fuse, this is arch dependent operation and may vary on different platforms. So add a interface for arch level initialization. Signed-off-by: Peng Fan <peng.fan@nxp.com>
2020-05-10thermal: imx_tmu: Add support for thermal sensor on iMX8MMPeng Fan
The analog sensors on iMX8MM are new, used for 14LPP process. So the Temperature Sensor Monitoring Unit (TMU) has some change accordingly. We use version 2 in TMU driver to represent the new TMU, so the one driver can service for both i.MX8MQ/M. Signed-off-by: Peng Fan <peng.fan@nxp.com>
2020-05-10thermal: Add thermal driver for i.MX8MPeng Fan
The driver is ported form Linux Kernel and support driver model. Users need to provide the tmu node and sensors nodes in DTB. Signed-off-by: Ye Li <ye.li@nxp.com> Signed-off-by: Peng Fan <peng.fan@nxp.com>
2020-05-10thermal: imx_scu_thermal: Update driver for i.MX8QM thermal sensorYe Li
Add iMX8QM thermal compatible string and its driver data. Signed-off-by: Ye Li <ye.li@nxp.com> Signed-off-by: Peng Fan <peng.fan@nxp.com>
2020-01-20thermal: ti-bandgap: Fix adc value datatypeFaiz Abbas
The CORE_TEMP_SENSOR_MPU register gives a raw adc value which needs to be indexed into a lookup table to get the actual temperature. Fix the naming and datatype of the adc value variable. Signed-off-by: Faiz Abbas <faiz_abbas@ti.com> Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
2019-07-19thermal: add i.MX8 thermal driverPeng Fan
Add i.MX8 thermal driver to support get temperature from SCU. Signed-off-by: Peng Fan <peng.fan@nxp.com>
2018-05-07SPDX: Convert all of our single license tags to Linux Kernel styleTom Rini
When U-Boot started using SPDX tags we were among the early adopters and there weren't a lot of other examples to borrow from. So we picked the area of the file that usually had a full license text and replaced it with an appropriate SPDX-License-Identifier: entry. Since then, the Linux Kernel has adopted SPDX tags and they place it as the very first line in a file (except where shebangs are used, then it's second line) and with slightly different comment styles than us. In part due to community overlap, in part due to better tag visibility and in part for other minor reasons, switch over to that style. This commit changes all instances where we have a single declared license in the tag as both the before and after are identical in tag contents. There's also a few places where I found we did not have a tag and have introduced one. Signed-off-by: Tom Rini <trini@konsulko.com>
2017-11-21thermal: ti-bandgap: Add support for temperature sensorFaiz Abbas
The dra7xx series of SOCs contain a temperature sensor and an associated analog-to-digital converter (ADC) which produces an output which is proportional to the SOC temperature. Add support for this temperature sensor. Signed-off-by: Faiz Abbas <faiz_abbas@ti.com> Reviewed-by: Simon Glass <sjg@chromium.org>
2017-05-18thermal: imx: fix calculationPeng Fan
Fix calculation. do_div can not handle negative values. Use div_s64_rem to handle the calculation. Signed-off-by: Peng Fan <peng.fan@nxp.com> Cc: Stefano Babic <sbabic@denx.de>
2017-05-18imx: thermal: update imx6 thermal driver according new equationPeng Fan
>From IC guys: " After a thorough accuracy study of the Temp sense circuit, we found that with our current equation, an average part can read 7 degrees lower than a known forced temperature. We also found out that the standard variance was around 2C; which is the tightest distribution that we could create. We need to change the temp sense equation to center the average part around the target temperature. " New equation: Tmeas = (Nmeas - n1) / slope + t1 + offset n1= fused room count t1= 25 offset=3.580661 slope= 0.4148468 – 0.0015423*n1 According the new equation, update the thermal driver. c1 and c2 changed to u64 type and update comments. Signed-off-by: Peng Fan <peng.fan@nxp.com> Cc: Stefano Babic <sbabic@denx.de>
2017-01-02imx: thermal: Kconfig: add MX7Peng Fan
The thermal drivers support i.MX6 and i.MX7, add MX7 in Kconfig file. Signed-off-by: Peng Fan <peng.fan@nxp.com> Cc: Stefano Babic <sbabic@denx.de>
2016-10-26thermal: Kconfig: Add IMX_THERMAL entryJagan Teki
Added kconfig for IMX_THERMAL driver. Cc: Simon Glass <sjg@chromium.org> Cc: Fabio Estevam <fabio.estevam@nxp.com> Cc: Stefano Babic <sbabic@denx.de> Cc: Peng Fan <peng.fan@nxp.com> Cc: Matteo Lisi <matteo.lisi@engicam.com> Cc: Michael Trimarchi <michael@amarulasolutions.com> Signed-off-by: Jagan Teki <jagan@amarulasolutions.com>
2016-05-05Fix various typos, scattered over the code.Robert P. J. Day
Spelling corrections for (among other things): * environment * override * variable * ftd (should be "fdt", for flattened device tree) * embedded * FTDI * emulation * controller
2016-01-07imx: mx7: fix the temperature checking for Rev1.1Peng Fan
To TO1.0, we can not rely on finish bit to read temperature. But to TO1.1, the issue was fixed by IC, we can rely on finish bit for temperature reading for TO1.1. Signed-off-by: Peng Fan <peng.fan@nxp.com> Cc: Stefano Babic <sbabic@denx.de> Cc: Tim Harvey <tharvey@gateworks.com> Cc: Fabio Estevam <fabio.estevam@freescale.com> Cc: Adrian Alonso <aalonso@freescale.com>
2015-09-13thermal: imx_thermal: Do not print on errorFabio Estevam
It is not very useful to have the message below on every boot (especially when we are using early silicon): U-Boot 2015.10-rc2-23945-g37cf215 (Sep 08 2015 - 14:12:14 -0300) CPU: Freescale i.MX6UL rev1.0 792 MHz (running at 396 MHz) CPU: Commercial temperature grade (0C to 95C)CPU: Thermal invalid data, fuse: 0x0 - invalid sensor device , so turn the error message into debug level. Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
2015-09-13thermal: imx: add imx7d soc thermal supportAdrian Alonso
Add imx7 SoC thermal driver support Signed-off-by: Adrian Alonso <aalonso@freescale.com>
2015-09-13thermal: imx_thermal: rework driver to be reusedAdrian Alonso
Rework imx_thermal driver to be used across i.MX processor that support thermal sensor Signed-off-by: Adrian Alonso <aalonso@freescale.com> Signed-off-by: Peng Fan <Peng.Fan@freescale.com>
2015-07-10thermal: imx_thermal: fix busywait if IMX6 temp <0CTim Harvey
The temperature calculation must be typecasted to keep the compiler from sign extending a negative value prior to division. This fixes an issue where if the CPU temperature is <0C it will get stuck in the busywait loop until the CPU heats up to 0C. Cc: Ye Li <b37916@freescale.com> Cc: Jason Liu <r64343@freescale.com> Signed-off-by: Tim Harvey <tharvey@gateworks.com>
2015-07-10thermal:imx_thermal: enter busywait cooling loop when over max CPU tempTim Harvey
Remove the check for temperature being within the min/max range and enter the busywait cooling loop whenever the CPU temperature is over the critical temp. This fixes the issue where if a board was booted at a temp greater than the CPU temperature max, it would skip the loop and never indicate or try to address the overtemp issue. Cc: Ye Li <b37916@freescale.com> Cc: Jason Liu <r64343@freescale.com> Signed-off-by: Tim Harvey <tharvey@gateworks.com>
2015-05-26thermal: imx_thermal: increase critical temperature thresholdTim Harvey
The CPU temperature grade from OTP is now used to define the critical threshold at which point we busyloop until we are below, however this threshold is still too low. Instead of 20C below the max CPU temperature, change it to 5C defined now by TEMPERATURE_HOT_DETLA for clarity. Rename 'passive' to 'critical' as that better defines our use case here. Additionally change the output of the busyloop message to show the max CPU temperature as well as current. Before: CPU Temperature is 101 C, too hot to boot, waiting... CPU Temperature is 101 C, too hot to boot, waiting... After: CPU Temperature (101C) too close to max (105C) waiting... CPU Temperature (101C) too close to max (105C) waiting... Cc: Stefan Roese <sr@denx.de> Cc: Eric Nelson <eric.nelson@boundarydevices.com> Cc: Heiko Schocher <hs@denx.de> Cc: Nikita Kiryanov <nikita@compulab.co.il> Cc: Jon Nettleton <jon.nettleton@gmail.com> Cc: Jason Liu <r64343@freescale.com> Cc: Ye Li <b37916@freescale.com> Cc: Fabio Estevam <fabio.estevam@freescale.com> Cc: Christian Gmeiner <christian.gmeiner@gmail.com> Cc: Markus Niebel <Markus.Niebel@tq-group.com> Cc: Peng Fan <b51431@freescale.com> Signed-off-by: Tim Harvey <tharvey@gateworks.com>
2015-05-19thermal: imx_thermal: use CPU temperature grade for trip pointsTim Harvey
Replace the hard-coded values for min/max/passive with values derived from the CPU temperature grade. Signed-off-by: Tim Harvey <tharvey@gateworks.com>
2015-02-12dm: Expand and complete Kconfig in drivers/Simon Glass
Expand the help messages for each driver. Add missing Kconfig for I2C, SPI flash and thermal. Signed-off-by: Simon Glass <sjg@chromium.org> Reviewed-by: Masahiro Yamada <yamada.m@jp.panasonic.com>
2014-12-01thermal: imx_thermal: Do not display calibration dataFabio Estevam
Printing the calibration data on every boot does not provide really useful information: U-Boot 2015.01-rc1-18266-ge7eb277 (Nov 24 2014 - 11:29:51) CPU: Freescale i.MX6Q rev1.2 at 792 MHz CPU: Thermal calibration data: 0x5d85067d CPU: Temperature 33 C Reset cause: POR Board: MX6-SabreSD Do not display the calibration data in order to have a cleaner boot log. Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
2014-11-21DM: thermal: Add imx thermal DM driverYe.Li
Add a new thermal uclass for thermal sensor and implement the imx thermal driver basing on this uclass. Signed-off-by: Ye.Li <B37916@freescale.com> Acked-by: Stefano Babic <sbabic@denx.de>