diff options
author | Jan Kiszka | 2019-01-03 09:08:42 +0100 |
---|---|---|
committer | Tom Rini | 2019-02-22 19:49:41 -0500 |
commit | 2ab6e74dbd667e77d88e3ffb1893515243e0c5ad (patch) | |
tree | 843de8548a76f9728676e97fcad769fc132555ae | |
parent | fca0128da48031286f0cb2414ee6c94e9162943c (diff) |
cmd: Kconfig: LED command depends on LED subsystems
Without CONFIG_LED, we get
cmd/built-in.o: In function `show_led_state':
cmd/led.c:40: undefined reference to `led_get_state'
cmd/built-in.o: In function `do_led':
cmd/led.c:99: undefined reference to `led_get_by_label'
cmd/led.c:108: undefined reference to `led_set_state'
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
-rw-r--r-- | cmd/Kconfig | 1 |
1 files changed, 1 insertions, 0 deletions
diff --git a/cmd/Kconfig b/cmd/Kconfig index 3ea42e42561..ed8d85bfa63 100644 --- a/cmd/Kconfig +++ b/cmd/Kconfig @@ -1399,6 +1399,7 @@ config CMD_DISPLAY config CMD_LED bool "led" + depends on LED default y if LED help Enable the 'led' command which allows for control of LEDs supported |