diff options
author | Amit Singh Tomar | 2020-04-19 19:28:28 +0530 |
---|---|---|
committer | Tom Rini | 2020-04-24 16:40:09 -0400 |
commit | 4939beea8e14314bc27ca343526c456ed75640fb (patch) | |
tree | 376d3103e1aec6da0d35a437d8d0f4defed65c6b /drivers/clk | |
parent | bf66584336351355cd487c166f645f12c2442925 (diff) |
arm: dts: sync dts for Action Semi S900
Synchronize device tree bindings with v5.5-rc6 tag with commit id
"b3a987b0264d".
Also, it removes older clock binding defined for S900 along with undocumented
compatible string "actions,s900-serial" from serial driver and adapts clock
driver to cater to new bindings.
Reviewed-by: Manivannan Sadhasivam <manivannan.sadhasivam@linaro.org>
Reviewed-by: Andre Przywara <andre.przywara@arm.com>
Signed-off-by: Amit Singh Tomar <amittomer25@gmail.com>
Diffstat (limited to 'drivers/clk')
-rw-r--r-- | drivers/clk/owl/clk_s900.c | 6 |
1 files changed, 3 insertions, 3 deletions
diff --git a/drivers/clk/owl/clk_s900.c b/drivers/clk/owl/clk_s900.c index a7c15d2812e..d60f199252a 100644 --- a/drivers/clk/owl/clk_s900.c +++ b/drivers/clk/owl/clk_s900.c @@ -12,7 +12,7 @@ #include <asm/arch-owl/regs_s900.h> #include <asm/io.h> -#include <dt-bindings/clock/s900_cmu.h> +#include <dt-bindings/clock/actions,s900-cmu.h> void owl_clk_init(struct owl_clk_priv *priv) { @@ -78,7 +78,7 @@ int owl_clk_enable(struct clk *clk) struct owl_clk_priv *priv = dev_get_priv(clk->dev); switch (clk->id) { - case CLOCK_UART5: + case CLK_UART5: owl_uart_clk_enable(priv); break; default: @@ -93,7 +93,7 @@ int owl_clk_disable(struct clk *clk) struct owl_clk_priv *priv = dev_get_priv(clk->dev); switch (clk->id) { - case CLOCK_UART5: + case CLK_UART5: owl_uart_clk_disable(priv); break; default: |