* SOCIONEXT Milbeaut SDHCI controller
This file documents differences between the core properties in mmc.txt
and the properties used by the sdhci_milbeaut driver.
Required properties:
- compatible: "socionext,milbeaut-m10v-sdhci-3.0"
- clocks: Must contain an entry for each entry in clock-names. It is a
list of phandles and clock-specifier pairs.
See ../clocks/clock-bindings.txt for details.
- clock-names: Should contain the following two entries:
"iface" - clock used for sdhci interface
"core" - core clock for sdhci controller
Optional properties:
- fujitsu,cmd-dat-delay-select: boolean property indicating that this host
requires the CMD_DAT_DELAY control to be enabled.
Example:
sdhci3: mmc@1b010000 {
compatible = "socionext,milbeaut-m10v-sdhci-3.0";
reg = <0x1b010000 0x10000>;
interrupts = <0 265 0x4>;
voltage-ranges = <3300 3300>;
bus-width = <4>;
clocks = <&clk 7>, <&ahb_clk>;
clock-names = "core", "iface";
cap-sdio-irq;
fujitsu,cmd-dat-delay-select;
};
|